Multiclass determination of 66 organic micropollutants in environmental water samples by fast gas chromatography-mass spectrometry.

نویسندگان

  • Laura Cherta
  • Joaquim Beltran
  • Tania Portolés
  • Félix Hernández
چکیده

A multiresidue method has been developed for quantification and identification of 66 multiclass priority organic pollutants in water by fast gas chromatography (GC) coupled to mass spectrometry (MS). Capabilities and limitations of single quadrupole mass spectrometer as detector in fast GC were studied evaluating the chromatographic responses in terms of sensitivity and chromatographic peak shapes, as they were influenced by scan time. The number of monitored ions in a selected ion monitoring (SIM) group strongly conditioned the scan time and subsequently the number of data points per peak. A compromise between peak shape and scan time was adopted in order to reach the proper conditions for quantitative analysis. An average of 10-15 points per peak was attained for most compounds, involving scan times between 0.1 and 0.22 s. The method was validated for mineral, surface, and groundwater. A solid-phase extraction pre-concentration step using C(18) cartridges was applied. Four isotopically labeled standards were added to the samples before extraction and used as surrogates to ensure a reliable quantification. Analyses were performed by GC-MS in electron ionization mode, monitoring the three most abundant and/or specific ions for each compound and using the intensity ratios as a confirmatory parameter. With a chromatographic run of less than 10 min, SIM mode provided excellent sensitivity and identification capability due to the monitoring of three ions and the evaluation of their intensity ratio. Limits of detection below 10 ng/L were reached for most of the 66 compounds in the three matrices studied. Accuracy and precision of the method were evaluated by means of recovery experiments at two fortification levels (10 and 100 ng/L), obtaining recoveries between 70% and 120% in most cases and relative standard deviations below 20%. The possibilities of a simultaneous SIM scan method have also been explored for non-target qualitative analysis. The developed method has been applied to the analysis of surface water samples collected from the Mediterranean region of Spain.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Microextraction techniques coupled to liquid chromatography with mass spectrometry for the determination of organic micropollutants in environmental water samples.

Until recently, sample preparation was carried out using traditional techniques, such as liquid-liquid extraction (LLE), that use large volumes of organic solvents. Solid-phase extraction (SPE) uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been ma...

متن کامل

Mass spectrometry for monitoring micropollutants in water.

Surface water reservoirs and aquifers are exposed to contamination by thousands of micropollutants from industrial, pharmaceutical, agricultural and natural origins. Most developed and developing countries implement a water-quality regulation programme to prevent contamination by such chemicals at illegal concentrations. Traditionally, analytical methods based on gas chromatography-mass spectro...

متن کامل

Simultaneous Determination of Disinfection By-products in Water Samples from Advanced Membrane Treatments by Headspace Solid Phase Microextraction and Gas Chromatography-Mass Spectrometry

A headspace-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry (GC-MS) method has been developed for the simultaneously determination of 20 disinfection by-products (DBPs) in water samples from reverse osmosis (RO) membranes. Selected compounds belong to different families including: trihalomethanes (THMs), halogenated acetonitriles (HANs), halogenated nitromethanes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 402 7  شماره 

صفحات  -

تاریخ انتشار 2012