An electric device for instantaneous and continuous computation of aortic blood velocity.

نویسندگان

  • D L FRY
  • A J MALLOS
  • F W NOBLE
چکیده

acceleration, a is the coefficient of friction, and u is the blood velocity. The boundary condition for u is that it must return to and remain at zero at the end of diastole. The value of a which will satisfy this condition is the proper value. It can be demonstrated that a must lie somewhere between 0 and 2A.-C. The proper value may be obtained by a tedious graphic method. However, analog computer technics are available which permit the adjustment of a to satisfy the boundary condition for u and which will then solve equation (1) for u continuously. An equation analogous to equation (1) is

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Water Velocity Measurements in Open Channels Using Volumetric Current Meter (VCM)

An innovative Volumetric Current Meter (VCM) was designed in order to allow quick velocity measurements in open channels. At first, the coefficient of velocity (Cv) of the device was determined through calibration under different water velocities in the laboratory. The measurement performance was verified by measurements performed in similar flows in irrigation channels using an ordinary curren...

متن کامل

Doppler ultrasound in the assessment of severity of coarctation of the aorta and interruption of the aortic arch.

Doppler ultrasound was used to investigate 48 infants and children (age 2 days-16 years, weight 1.0-58 kg) with aortic arch abnormalities. In only 38 of the 42 with an important coarctation was an increased blood flow velocity from the distal arch demonstrated. In three with interruption of the aortic arch an increased velocity recorded from the region of the distal arch was thought to represen...

متن کامل

A Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data

Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...

متن کامل

Performance Analysis Of Mono-bit Digital Instantaneous Frequency Measurement (Difm) Device

Instantaneous Frequency Measurement (IFM) devices are the essential parts of anyESM, ELINT, and RWR receiver. Analog IFMs have been used for several decades. However, thesedevices are bulky, complex and expensive. Nowadays, there is a great interest in developing a wideband, high dynamic range, and accurate Digital IFMs. One Digital IFM that has suitably reached allthese requirements is mono-bi...

متن کامل

Mathematical Simulation for the Effects of Flow Control Devices in a Six- strand Tundish in Continuous Casting of Steel Billet

The method of continuous casting of steel is now often used in the metallurgical industry, due to the increasing demand for the production of high – quality steel. An important device of continuous casting machine is the tundish, in which a stabilized steel flow has a crucial effect on the quality and efficiency conditions of the continuous casting process. In this study fluid flows in a six – ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 5 1  شماره 

صفحات  -

تاریخ انتشار 1957