Skin dose measurement for patients using imaging plates in interventional radiology procedures.

نویسندگان

  • Hiroko Ohuchi
  • Toshimitsu Satoh
  • Yoichi Eguchi
  • Yuji Kaga
  • Takeshi Arai
  • Shin-ichi Suzuki
  • Akira Yamadera
چکیده

A method using europium-doped BaFBr imaging plates (IPs) has been developed to estimate and map values of entrance skin doses during interventional radiology (IR). IPs offer many advantages for measuring the entrance skin dose because they have a wide dynamic range (up to 100 Gy), provide high spatial resolution as a detector of two-dimensional images, and can be used repeatedly. The entrance skin dose was measured by fitting a 40x40 cm IP sheet around a patient's back using a corset in clinical studies involving IR procedures at two hospitals. The corset can minimize a geometric discrepancy in dose estimates between the IP and the patient body. The entrance skin dose was measured by using photoluminescent glass dosimeters simultaneously, and both values were compared. The spatial relative dose profiles from both dose estimates showed generally good agreement; however, the doses obtained with glass dosimeter chips were often lower than those obtained with IPs. This discrepancy comes from a radiation shielding effect for x rays by IPs and a strong angular dependence of the glass dosimeter in low energy x-ray fields. Comprehensive results of this study demonstrated that IPs were able to measure entrance skin dose in even high dose regions with steep dose gradients and to determine the peak skin dose, without missing hot spots, over all ranges used during interventional radiology procedures. Use of the corset minimized variations associated with angular dependence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital

Introduction:   Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as  the  2nd  contributing  factor in  increasing  the  amount  of  public  doses  in various societies. So that related radiation protection organization has recommended measuring patient d...

متن کامل

Assessment of patients’ entrance skin and effective dose in a mathematical human phantom for the most common interventional radiological examinations

Introduction: Nowadays, we are witnessing an exponential use of interventional radiology techniques in different communities. After CT, interventional techniques are the second factor of increasing patients’ doses in different societies. Measuring patient doses from aforementioned methods has been recommended by many radiation protection professional organizations such as ICRP...

متن کامل

Evaluation of Maximum Patient Skin Dose Arising from Interventional Cardiology Using Thermoluminescence Dosimeter in Mashhad, Iran

Introduction The increasing practice of interventional fluoroscopy in diagnosis and treatment of cardiovascular disease has risen attention to improve radiation protection of patients and cardiologists in these relatively high dose techniques. Therefore, nowadays there is an emphasis on the measurement of radiation dose received by patients and cardiologists arising from the relevant procedures...

متن کامل

Comprehensive TLD dosimetry of physicians and patients during interventional angiography procedures to estimate the risk of radiation deterministic effect

Introduction: Interventional angiography procedures are increasingly used today. These techniques require a long time of standing near the patient and x-ray tube which lead to increase the radiation-dose of the staff and interventionists. This may also, in turn, lead to the occurrence of radiation deterministic effects. Since a large number of interventional radiology were perf...

متن کامل

Improved Imaging Plate Dosimetry for X-rays in Interventional Radiology

A new method using imaging plates (IPs) to evaluate patient doses in interventional radiology (IR) procedures is developed. IPs are made of photostimulated luminescence (PSL) materials, are highly sensitive two-dimensional radiation sensors, and can be reused repeatedly. Mapping skin doses in complex fluoroscopy interventions helps determine the probability of a possible injury, helps find area...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 93 1  شماره 

صفحات  -

تاریخ انتشار 2007