Nine-year outcome after anatomic stemless shoulder prosthesis: clinical and radiologic results.

نویسندگان

  • Nael Hawi
  • Petra Magosch
  • Mark Tauber
  • Sven Lichtenberg
  • Peter Habermeyer
چکیده

BACKGROUND Several stemless shoulder implants are available on the market, but only a few studies have presented results with sufficient mid- to long-term follow-up. The present study evaluated clinical and radiologic outcomes 9 years after anatomic stemless shoulder replacement. METHODS This is a prospective cohort study evaluating the stemless shoulder prosthesis since 2005. Anatomic stemless shoulder replacement using a single prosthesis was performed in 49 shoulders; 17 underwent total shoulder replacement, and 32 underwent hemiarthroplasty. Forty-three patients were clinically and radiologically monitored after a mean of 9 years (range, 90-127 months; follow-up rate, 88%). The indications for shoulder replacement were primary osteoarthritis in 7 shoulders, post-traumatic in 24, instability in 7, cuff tear arthropathy in 2, postinfectious arthritis in 1, and revision arthroplasty in 2. RESULTS The Constant-Murley Score improved significantly from 52% to 79% (P < .0001). The active range of motion also increased significantly for flexion from 101° to 118° (P = .022), for abduction from 79° to 105° (P = .02), and for external rotation from 21° to 43° (P < .0001). Radiologic evaluation revealed incomplete radiolucency in 1 patient without clinical significance or further intervention. No revision caused by loosening or countersinking of the humeral implant was observed. CONCLUSIONS The 9-year outcome after stemless shoulder replacement is comparable to that of third- and fourth-generation standard shoulder arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Are there differences between stemless and conventional stemmed shoulder prostheses in the treatment of glenohumeral osteoarthritis?

BACKGROUND Conventional stemmed anatomical shoulder prostheses are widely used in the treatment of glenohumeral osteoarthritis. The stemless shoulder prosthesis, in contrast, is a new concept, and fewer outcome studies are available. Therefore, the purpose of the study was to investigate the early functional outcome and postoperative proprioception of a stemless prosthesis in comparison with a ...

متن کامل

Is the stemless humeral head replacement clinically and radiographically a secure equivalent to standard stem humeral head replacement in the long-term follow-up? A prospective randomized trial.

BACKGROUND Stemless humeral head replacement represents a young generation of shoulder arthroplasty. This study evaluated the differences of this new stemless design compared with the fourth-generation standard stemmed design. METHODS Total shoulder arthroplasty was performed in 20 patients with a stemless shoulder prosthesis (group 1) and in 20 patients with a standard stem humeral head repl...

متن کامل

Radiological changes do not influence clinical mid-term outcome in stemless humeral head replacements with hollow screw fixation: a prospective radiological and clinical evaluation

BACKGROUND Stemless shoulder arthroplasty is a fairly new concept. Clinical and radiological follow-up is essential to prove implant safety and concept. This prospective single-centre study was performed to evaluate the influence of radiological changes on clinical mid-term outcome following stemless humeral head replacement with hollow screw fixation. METHODS Short- and mid-term radiological...

متن کامل

Anatomic stemless shoulder arthroplasty and related outcomes: a systematic review

BACKGROUND The latest generation of shoulder arthroplasty includes canal-sparing respectively stemless designs that have been developed to allow restoration of the glenohumeral center of rotation independently from the shaft, and to avoid stem-related complications. The stemless prosthesis design has also recently been introduced for use in reverse arthroplasty systems. METHODS We systematica...

متن کامل

Restoration of the joint geometry and outcome after stemless TESS shoulder arthroplasty

AIM To evaluate the joint geometry and the clinical outcome of stemless, anatomical shoulder arthroplasty with the TESS system. METHODS Twenty-one shoulders with a mean follow-up 18 of months were included. On scaled digital radiographs the premorbid center of rotation (CoR) was assessed and compared to the CoR of the prosthesis by using the MediCAD® software. Additionally, the pre- and post-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 26 9  شماره 

صفحات  -

تاریخ انتشار 2017