Customized Guide for Femoral Component Positioning in Hip Resurfacing Arthroplasty

نویسندگان

  • Chaturong Pornrattanamaneewong
  • Rapeepat Narkbunnam
  • Keerati Chareancholvanich
چکیده

OBJECTIVE To prove the accuracy of a customized guide developed according to our method. METHODS This customized guide was developed from a three-dimensional model of proximal femur reconstructed using computed tomography data. Based on the new technique, the position of the guide pin insertion was selected and adjusted using the reference of the anatomical femoral neck axis. The customized guide consists of a hemispheric covering designed to fit the posterior part of the femoral neck. The performance of the customized guide was tested in eight patients scheduled for total hip arthroplasty. The stability of the customized guide was assessed by orthopedic surgeons. An intraoperative image intensifier was used to assess the accuracy. RESULTS The customized guide was stabilized with full contact and was fixed in place in all patients. The mean angular deviations in relation to the what was planned in anteroposterior and lateral hip radiographs were 0.5º ± 1.8º in valgus and 1.0º ± 2.4º in retroversion, respectively. CONCLUSION From this pilot test, the authors suggest that the proposed technique could be applied as a customized guide to the positioning device for hip resurfacing arthroplasty with acceptable accuracy and user-friendly interface. Level of Evidence IV, Cases Series.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A simple and reliable technique for placing the femoral neck guide pin in hip resurfacing arthroplasty.

Early failure of hip resurfacing has been attributed to component malposition and other factors. Accurate placement of the femoral guide pin is challenging with commercial guides, and computer navigation adds considerable cost to the procedure. Precise pin placement can be achieved by drilling a 2.8-mm pin across the hip joint in a retrograde fashion similar to placing a dynamic hip screw pin. ...

متن کامل

Cement Penetration into Femoral Head with Longitudinal Slot Following Hip Resurfacing Arthroplasty

+Snyder, S; Jamali, A A; Hazelwood, S J +California Polytechnic State University, San Luis Obispo, CA, University of California Davis Medical Center, Sacramento, CA [email protected] INTRODUCTION Hip resurfacing arthroplasty is seen as advantageous in younger, active patients due to its preservation of bone. Failure of these implants, though, can be very traumatic and potentially life threat...

متن کامل

Hip Resurfacing Arthroplasty: Investigating the Femoral Component in the Sagittal Plane

The outcomes of hip resurfacing arthroplasty are largely dependent on prosthesis positioning. The biomechanics of notching, accurate measurement of femoral implant version and the use of computer navigation of the Birmingham Hip Resurfacing procedure were studied in this work. First, biomechanical tests were conducted with varying notch sizes and femoral positions, and it was determined that an...

متن کامل

The effect of component size and orientation on the concentrations of metal ions after resurfacing arthroplasty of the hip.

Increased concentrations of metal ions after metal-on-metal resurfacing arthroplasty of the hip remain a concern. Although there has been no proven link to long-term health problems or early prosthetic failure, variables associated with high metal ion concentrations should be identified and, if possible, corrected. Our study provides data on metal ion levels from a series of 76 consecutive pati...

متن کامل

Resurfacing arthroplasty of the hip for avascular necrosis of the femoral head: a minimum follow-up of four years.

We performed 96 Birmingham resurfacing arthroplasties of the hip in 71 consecutive patients with avascular necrosis of the femoral head. A modified neck-capsule-preserving approach was used which is described in detail. The University of California, Los Angeles outcome score, the radiological parameters and survival rates were assessed. The mean follow-up was for 5.4 years (4.0 to 8.1). All the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 25  شماره 

صفحات  -

تاریخ انتشار 2017