Laser nephelometric measurement of seven serum proteins compared with radial immunodiffusion.

نویسندگان

  • M Guiguet
  • P Padieu
  • G Mack
  • M Dalebroux
چکیده

Quantification of immunoglobulins IgG, IgA, IgM, C3 complement, siderophilin, alpha 2-macroglobulin and haptoglobin in serum by a Behring laser nephelometer coupled with a date processing apparatus was compared with values obtained by the radial immunodiffusion method of Mancini. The precision was not improved by the use of the laser nephelometer as compared to Mancini radial immunodiffusion, but within run precision was better than that among runs for both methods. The analytical recovery studies for laser nephelometry showed a close concordance between the theoretical and measured values for all proteins. The two techniques were also compared by means of correlation studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of laser nephelometry in the measurement of serum proteins.

Measurement of immunoglobulins (Ig) and of complement component C3 in human serum by automated and manual nephelometric techniques is tedious, and the effective linear range is too narrow. We describe a laser nephelometer/reagent system for measuring serum proteins by the use of forward light scatter (which enhances the ratio of reaction/blank), electronic blank subtraction, laser light (632 nm...

متن کامل

Three immunoassay methods evaluated for quantifying prealbumin (transthyretin) in serum.

We developed an immunoturbidimetric assay for prealbumin on the Cobas Bio centrifugal analyzer and compared results from this assay with those from a rate nephelometric assay (Beckman Instruments Inc.) and a radial immunodiffusion kit (Behring Diagnostics). All three assays were evaluated for precision, linearity, and correlation to each other for analysis of sera from pediatric patients. All a...

متن کامل

Nephelometric measurement of ceruloplasmin with a centrifugal analyzer.

We describe a rapid nephelometric assay for measurement of ceruloplasmin in serum with the Multistat centrifugal analyzer. In establishing the optimum conditions, the concentration of polyethylene glycol was critical. With a 30 g/L solution of polyethylene glycol, the calibrators and samples react at the same rate, while with a 60/L solution the calibrators react faster than the samples. The re...

متن کامل

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

Determination of alpha-1 antitrypsin by a nephelometric procedure.

Several reports exist which link low levels of serum alpha-1 antitrypsin with pulmonary emphysema. 3 ’9 ’13 Deficiency of this protein may be detected by serum electrophoresis or specifically quantitated by radial immunodiffusion. Recent investigations have led to the development of a number of automated and manual procedures for the quantitation of immunochemical reactions in aqueous media thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 1983