Hemostatic efficacy of chitosan-based bandage for closure of percutaneous arterial access sites: An experimental study in heparinized sheep model

نویسندگان

  • Pawanrat Kranokpiraksa
  • Dusan Pavcnik
  • Hideaki Kakizawa
  • Barry T. Uchida
  • Miran Jeromel
  • Frederick S. Keller
  • Josef Rösch
چکیده

BACKGROUND Most of the presently used percutaneous arterial closure devices (PACD) for hemostasis after interventional vascular procedures are effective, but carry risk of complications by deposition of a foreign body. A new promising externally applied PACD - chitosan-based HemCon Bandage (HCB) was explored in sheep. The HCB hemostatic efficacy and complications occurring with its use were compared to those with the standard manual compression (SMC). MATERIAL AND METHODS Both superficial femoral arteries (SFA) of 9 heparinized sheep were catheterized with an 8F sheath for 5 minutes. After the sheath withdrawal, hemostasis with the HCB was compared with hemostasis achieved with SMC in the contralateral SFA. Iliac angiograms performed by carotid artery approach determined the hemostasis time. RESULTS The HCB use shortened time to hemostasis with a mean time of 6.9 ± 3.9 minutes versus 10.8 ± 2.8 minutes for the SMC (P-value 0.019). Seven SFAs in the HCB group and only 1 SFA in the SMC group exhibited hemostasis in 5 minutes. All nine SFAs using the HCB showed femoral artery patency and demonstrated less hematoma (2/9) than in the SMC group (8/9). No complications developed in the HCB group, one SFA occlusion was seen in the SMC group. CONCLUSIONS The externally applied HCB in heparinized sheep was safe and effective. It significantly shortened time to hemostasis at the SFA access sites following 8F sheath removal. Proper application of the HCB was necessary to shorten hemostasis and prevent hematoma formation. The HCB should be tested in a clinically controlled study to evaluate its efficacy in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new kaolin-based hemostatic bandage use after coronary diagnostic and interventional procedures.

BACKGROUND Bleeding and vascular access site complications are an important cause of morbidity after percutaneous femoral procedures. Together with collagen-based and suture-based vascular closure devices, new hemostatic dressings have been developed to control heavy bleeding. AIM OF STUDY To evaluate safety and efficacy results of the first clinical QuikClot Interventional Hemostatic Bandage...

متن کامل

Chitosan Hemostatic Dressing for Renal Parenchymal Wound Sealing in a Porcine Model: Implications for Laparoscopic Partial Nephrectomy Technique

BACKGROUND AND OBJECTIVES This study was to evaluate the feasibility of using a novel chitosan hemostatic dressing to control hemorrhage and urinary leakage by sealing off the parenchymal wound following LPN. METHODS Nine heparinized domestic swine underwent bilateral laparoscopic partial nephrectomies involving either a polar or wedge resection. Estimated blood loss (EBL), hemostatic score, ...

متن کامل

Hemostatic efficacy of local chitosan linear polymer granule in an experimental sheep model with severe bleeding of arteria and vena femoralis.

BACKGROUND The aim of the present study was to evaluate the hemostatic effect of chitosan linear polymer in a sheep model with femoral bleeding. METHODS Following induction of anesthesia and intubation of sheep, groin injury was induced to initiate hemorrhage. Animals were randomly assigned to study and control groups. In the control group, absorbent pads were packed on the wound, and pressur...

متن کامل

Vascular hemostasis bandage compared to standard manual compression after cardiac catheterization in children.

BACKGROUND Femoral venous and arterial approaches are the commonly used to obtain vascular access for pediatric cardiac catheterization. Hemostasis after catheter removal is usually obtained by manual compression. However, this technique is time consuming and at times painful. Although several closure devices are available for adults, they are not widely applicable in children. OBJECTIVES To ...

متن کامل

A novel vascular sealing device for closure of percutaneous arterial access sites.

The purpose of this study was to investigate the safety and efficacy of a novel vascular sealing device that incorporates a unique low-profile balloon-positioning catheter and a procoagulant delivered after diagnostic cardiac catheterization and percutaneous transluminal coronary angioplasty (PTCA) procedures. Current management of the vascular access site after percutaneous interventions is as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2010