Intramyocardial oxygen transport by quantitative diffuse reflectance spectroscopy in calves.

نویسندگان

  • Tobias Lindbergh
  • Marcus Larsson
  • Zoltán Szabó
  • Henrik Casimir-Ahn
  • Tomas Strömberg
چکیده

Intramyocardial oxygen transport was assessed during open-chest surgery in calves by diffuse reflectance spectroscopy using a small intramuscular fiber-optic probe. The sum of hemo- and myoglobin tissue fraction and oxygen saturation, the tissue fraction and oxidation of cytochrome aa3, and the tissue fraction of methemoglobin were estimated using a calibrated empirical light transport model. Increasing the oxygen content in the inhaled gas, 21%-50%-100%, in five calves (group A) gave an increasing oxygen saturation of 19+/-4%, 24+/-5%, and 28+/-8% (p<0.001, ANOVA repeated measures design) and mean tissue fractions of 1.6% (cytochrome aa3) and 1.1% (hemo- and myoglobin). Cardiac arrest in two calves gave an oxygen saturation lower than 5%. In two calves (group B), a left ventricular assistive device (LVAD pump) was implanted. Oxygen saturation in group B animals increased with LVAD pump speed (p<0.001, ANOVA) and with oxygen content in inhaled gas (p<0.001, ANOVA). The cytochrome aa3 oxidation level was above 96% in both group A and group B calves, including the two cases involving cardiac arrest. In conclusion, the estimated tissue fractions and oxygenation/oxidation levels of the myocardial chromophores during respiratory and hemodynamic provocations were in agreement with previously presented results, demonstrating the potential of the method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative optical spectroscopy: a robust tool for direct measurement of breast cancer vascular oxygenation and total hemoglobin content in vivo.

We propose the use of a robust, biopsy needle-based, fiber-optic tool for routine clinical quantification of tumor oxygenation at the time of diagnostic biopsy for breast cancer. The purpose of this study was to show diffuse reflectance spectroscopy as a quantitative tool to measure oxygenation levels in the vascular compartment of breast cancers in vivo via an optical biopsy technique. Thirty-...

متن کامل

Quantitative Diffuse Reflectance Spectroscopy

In the field of biomedical optics, diffuse reflectance spectroscopy (DRS) is a frequently used technique for obtaining information about the optical properties of the medium under investigation. The method utilizes spectral difference between incident and backscattered light intensity for quantifying the underlying absorption and scattering processes that affects the light-medium interaction. I...

متن کامل

Instrument independent diffuse reflectance spectroscopy.

Diffuse reflectance spectroscopy with a fiber optic probe is a powerful tool for quantitative tissue characterization and disease diagnosis. Significant systematic errors can arise in the measured reflectance spectra and thus in the derived tissue physiological and morphological parameters due to real-time instrument fluctuations. We demonstrate a novel fiber optic probe with real-time, self-ca...

متن کامل

Spectroscopic Based Quantitative Mapping of Contaminant Elements in Dumped Soils of a Copper Mine

Possibility of mapping the distribution of Arsenic and Chromium in a mining area was investigated using combination of (VNIR) reflectance spectroscopy and geostatistical analysis. Fifty five soil samples were gathered from a waste dump at Sarcheshmeh copper mine and VNIR reflectance spectra were measured in a laboratory. Savitzky- Golay first derivative was used as the main pre-processing metho...

متن کامل

Determination of hydrochlorothiazide in pharmaceutical formulations by diffuse reflectance spectroscopy

This paper describes a method for quantitative spot test analysis of hydrochlorothiazide using diffuse reflectance spectroscopy. The reflectance measurements were performed analyzing the colored compound (l = 585 nm) produced from the reaction between hydrochlorothiazide and pdimethylaminocinnamaldehyde (PDAC) in acid medium. This reaction occurred on filter paper after heating to 80oC for 8 mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 15 2  شماره 

صفحات  -