Impact of Different Screw Designs on Durability of Fracture Fixation: In Vitro Study with Cyclic Loading of Scaphoid Bones

نویسندگان

  • Dominik Gruszka
  • Robert Herr
  • Hans Hely
  • Peer Hofmann
  • Daniela Klitscher
  • Alexander Hofmann
  • Pol Maria Rommens
  • Gwendolen Reilly
چکیده

PURPOSE The use of new headless compression screws (HCSs) for scaphoid fixation is growing, but the nonunion rate has remained constant. The aim of this study was to compare the stability of fixation resulting from four modern HCSs using a simulated fracture model to determine the optimal screw design(s). METHODS We tested 40 fresh-frozen cadaver scaphoids treated with the Acumed Acutrak 2 mini (AA), the KLS Martin HBS2 midi (MH), the Stryker TwinFix (ST) and the Synthes HCS 3.0 with a long thread (SH). The bones with simulated fractures and implanted screws were loaded uniaxially into flexion for 2000 cycles with a constant bending moment of 800 Nmm. The angulation of the fracture fragments was measured continuously. Data were assessed statistically using the univariate ANOVA test and linear regression analysis, and the significance level was set at p < 0.05. RESULTS The median angulation of bone fragments φ allowed by each screw was 0.89° for AA, 1.12° for ST, 1.44° for SH and 2.36° for MH. With regards to linear regression, the most reliable curve was achieved by MH, with a coefficient of determination of R2 = 0.827. This was followed by AA (R2 = 0.354), SH (R2 = 0.247) and ST (R2 = 0.019). Data assessed using an adapted ANOVA model showed no statistically significant difference (p = 0.291) between the screws. CONCLUSIONS The continuous development of HCSs has resulted in very comparable implants, and thus, at this time, other factors, such as surgeons' experience, ease of handling and price, should be taken into consideration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Screw Length on Fixed Proximal Scaphoid Fracture Biomechanics: In Vitro Study with Cyclic Loading and Load to Failure

Introduction: Internal fixation used as treatment for scaphoid fractures has increased with advances in surgical techniques [1]. Proximal pole scaphoid fractures present a clinical challenge due to their lower success rate when cast immobilization and internal fixation are utilized [2]. Screws maximizing length have been shown to impact wrist motion for fixed scaphoid waist fractures [3]. Addit...

متن کامل

Closed K-wire Fixation for the Treatment of Perilunate Dislocation and Trans-Scaphoid Perilunate Fracture Dislocations without Ligamentous Repair: Short Term Follow-Up

Background: The purpose of this study was to evaluate the treatment outcomes of perilunate dislocations (PLDs) andtransscaphoid perilunate fracture dislocations (TSPLDs) treated with operative volar approach without ligament repairor reconstruction.Methods: A total of seven patients (10 hands) were studied during 2017-2018. We fixed scaphoid fractures thorougha volar app...

متن کامل

Comparison of the Effect of Two Different Abutment Diameters on Detorque Value Using Cyclic Loading and Thermocycling

Background and Aim: Screw loosening is a common problem with both screw-retained and cemented implant restorations. It is assumed that the abutment diameter affects detorque value and screw loosening. We aimed to determine the effect of two different abutment diameters on detorque value using cyclic loading and thermocycling. Materials and Methods: This in-vitro experimental study was conducte...

متن کامل

The Importance of Screw Design in Scaphoid Fracture Fixation

The purpose of this study was to determine the influence of gender, screw design, and the approach on maximal screw length in scaphoid fracture fixation. Measurements were performed on 3D reconstructions of 20 CT scans of normal scaphoids. A comparison was made between 15 different available screw designs and between volar and dorsal screw placement. The length of the scaphoid along its central...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016