Respiration based steering for high intensity focused ultrasound liver ablation.

نویسندگان

  • Andrew B Holbrook
  • Pejman Ghanouni
  • Juan M Santos
  • Charles Dumoulin
  • Yoav Medan
  • Kim Butts Pauly
چکیده

PURPOSE Respiratory motion makes hepatic ablation using high intensity focused ultrasound (HIFO) challenging. Previous HIFU liver treatment had required apnea induced during general anesthesia. We describe and test a system that allows treatment of the liver in the presence of breathing motion. METHODS Mapping a signal from an external respiratory bellow to treatment locations within the liver allows the ultrasound transducer to be steered in real time to the target location. Using a moving phantom, three metrics were used to compare static, steered, and unsteered sonications: the area of sonications once a temperature rise of 15°C was achieved, the energy deposition required to reach that temperature, and the average rate of temperature rise during the first 10 s of sonication. Steered HIFU in vivo ablations of the porcine liver were also performed and compared to breath-hold ablations. RESULTS For the last phantom metric, all groups were found to be statistically significantly different (P ≤ 0.003). However, in the other two metrics, the static and unsteered sonications were not statistically different (P > 0.9999). Steered in vivo HIFU ablations were not statistically significantly different from ablations during breath-holding. CONCLUSIONS A system for performing HIFU steering during ablation of the liver with breathing motion is presented and shown to achieve results equivalent to ablation performed with breath-holding.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Towards real-time tracking of anatomic features for HIFU beam steering

Introduction A challenge for High Intensity Focused Ultrasound (HIFU) therapy in the upper abdomen is maintaining the ultrasound focal spot on the target during free breathing. Normal breathing can cause liver tissue to move by as much as 5.5 cm[1]. Consequently, current approaches require the patient to hold their breath during the deposition of focused ultrasound[2]. This practice assumes tha...

متن کامل

Spontaneous breathing vs. mechanical ventilation for respiratory-gated MR-HIFU ablation in the liver

Background/introduction Magnetic resonance-guided High Intensity Focused Ultrasound (MR-HIFU) ablation in the liver is complicated by the continuous motion of the target due to the respiratory cycle. Several motion compensation strategies have been proposed in the past, such as breathholding, respiratory gating and dynamic beam steering. Respiratory gating for sonication and MR thermometry uses...

متن کامل

High-intensity focused ultrasound tumor ablation: review of ten years of clinical experience.

High-intensity focused ultrasound (HIFU) is a technique to destroy tissue at depth within the body, selectively and without harming overlying and adjacent structures within the path of the beam because the ultrasonic intensity at the beam focus is much higher than that outside of the focus. Diagnostic ultrasound is the first imaging modality used for guiding HIFU ablation. In 1997, a patient wi...

متن کامل

High-intensity focused ultrasound provides palliation for liver metastasis causing gastric outlet obstruction: case report

BACKGROUND Surgery is the standard of care in several oncologic diseases. However, when non-surgical candidates are not suitable for radical treatment, palliation must be achieved at least. High-intensity focused ultrasound uses ultrasound power that can be sharply focused for highly localised application, as it is a completely non-invasive procedure. Its non-invasiveness appears to be of param...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2014