Design and evaluation of a human immunodeficiency virus type 1 RNA assay using nucleic acid sequence-based amplification technology able to quantify both group M and O viruses by using the long terminal repeat as target.
نویسندگان
چکیده
Currently available human immunodeficiency virus type 1 (HIV-1) RNA quantification assays can detect most viruses of the group M subtypes, but a substantial number are missed or not quantified reliably. Viruses of HIV-1 group O cannot be detected by any commercially available assay. We developed and evaluated a quantitative assay based on nucleic acid sequence-based amplification (NASBA) technology, with primers and probes located in the conserved long terminal repeat (LTR) region of the HIV-1 genome. In 68 of 72 serum samples from individuals infected with HIV-1 subtypes A to H of group M, viruses could be detected and quantified. In serum samples from two patients infected with HIV-1 group O viruses, these viruses as well could be detected and quantified. In contrast, the currently used gag-based assay underestimated the presence of subtype A viruses and could not detect subtype G and group O viruses. The discrepancy between the results of the two assays may be explained by the number of mismatches found within and among the probe and primer regions of the subtype isolates. These data indicate that LTR-based assays, including the NASBA format chosen here, are better suited to monitoring HIV-1 therapy than are gag-based assays in an era in which multiple HIV-1 subtypes and groups are spreading worldwide.
منابع مشابه
Evaluation of Nucleic Acid Sequence Based Amplification (NASBA) and Reverse Transcription Polymerase Chain Reaction for Detection of Coxsackievirus B3 in Cell Culture and Animal Tissue Samples
Enteroviruses are the causative agents of a number of diseases in humans. Group B coxsackieviruses are believed to be the most common viral agents responsible for human heart disease. Genomic data of enteroviruses has allowed developing new molecular approaches such as Nucleic Acid Sequence Based Amplification (NASBA) for detection of such viruses. In this study, coxsackievirus B3 (CVB3) was de...
متن کاملSingle rapid real-time monitored isothermal RNA amplification assay for quantification of human immunodeficiency virus type 1 isolates from groups M, N, and O.
Because human immunodeficiency virus type 1 (HIV-1) subtypes and circulating recombinant forms (CRFs) are spreading rapidly worldwide and are becoming less confined to a geographical area, RNA assays that can detect and quantify all HIV-1 isolates reliably are in demand. We have developed a fast, real-time monitored RNA assay based on an isothermal nucleic acid sequence-based amplification tech...
متن کاملReal-time PCR quantification of genital shedding of herpes simplex virus (HSV) and human immunodeficiency virus (HIV) in women coinfected with HSV and HIV.
The accuracy and usefulness of laboratory-developed real-time PCR procedures using a Light Cycler instrument (Roche Diagnostics) for detecting and quantifying human immunodeficiency virus type 1 (HIV-1) RNA and DNA as well as herpes simplex virus type 1 (HSV-1)/HSV-2 DNA in cervicovaginal secretions from women coinfected with HIV and HSV were evaluated. For HIV-1, the use of the NEC152 and NEC1...
متن کاملطراحی و راه اندازی روش TaqMan Real-time PCR جهت تشخیص و تعیین کمی ویروس نقص ایمنی اکتسابی نوع1 (HIV-1)
Background: Human Immunodeficiency Virus Type 1 (HIV-1) is one of the most important blood-borne infectious viruses that are considered a global problem, thus it is important to diagnose it with high accuracy and sensitivity. Serologic methods do not adequately detect this infection. Therefore, the purpose of the present study was to design a sensitive method based on TaqMan Real-time PCR me...
متن کاملA Simple and Rapid Method for the Detection of HIV-1/HCV in Co-Infected Patients
Background: Due to some limitations of serological methods in diagnosis of patients infected with HIV-1 (human immunodeficiency virus) and HCV (hepatitis C virus), it is profoundly important to use molecular methods for the detecting of these infectious agents. However, the most significant problems are the exorbitant cost of these methods and the need of a thermocycler which is an expensive...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 37 6 شماره
صفحات -
تاریخ انتشار 1999