Evaluation of a Multicommuted Flow System for Photometric Environmental Measurements

نویسندگان

  • Eva Ródenas-Torralba
  • Fábio R. P. Rocha
  • Boaventura F. Reis
  • Ángel Morales-Rubio
  • Miguel de la Guardia
چکیده

A portable flow analysis instrument is described for in situ photometric measurements. This system is based on light-emitting diodes (LEDs) and a photodiode detector, coupled to a multipumping flow system. The whole equipment presents dimensions of 25 cm x 22 cm x 10 cm, weighs circa 3 kg, and costs 650 euro. System performance was evaluated for different chemistries without changing hardware configuration for determinations of (i) Fe(3+) with SCN(-), (ii) iodometric nitrite determination, (iii) phenol with sodium nitroprusside, and (iv) 1-naphthol-N-methylcarbamate (carbaryl) with p-aminophenol. The detection limits were estimated as 22, 60, 25, and 60 ng mL (-1) for iron, nitrite, phenol, and carbaryl at the 99.7% confidence level with RSD of 2.3, 1.0, 1.8, and 0.8%, respectively. Reagent and waste volumes were lower than those obtained by flow systems with continuous reagent addition. Sampling rates of 100, 110, 65, and 72 determinations per hour were achieved for iron, nitrite, phenol, and carbaryl determinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Environmental Friendly Procedure for Photometric Determination of Hypochlorite in Tap Water Employing a Miniaturized Multicommuted Flow Analysis Setup

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4',4''-methylidynetris (N,N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assem...

متن کامل

A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step

A highly sensitive analytical procedure for photometric determination of molybdenum in plant materials was developed and validated. This procedure is based on the reaction of Mo(V) with thiocyanate ions (SCN-) in acidic medium to form a compound that can be monitored at 474 nm and was implemented employing a multicommuted flow analysis setup. Photometric detection was performed using an LED-bas...

متن کامل

An Automated Multicommuted Flow Analysis Procedure for Photometric Determination of Reducing Sugars in Wine Employing a Directly Heated Flow‐Batch Device

This work presents an automated analytical procedure for the photometric determination of reducing sugars in wines. The procedure is based on the reaction of reducing sugars with potassium hexacyanoferrate(III) in an alkaline medium, and was implemented employing a multicommuted flow analysis (MCFA) approach. Sample heating to promote the reaction was accomplished using a flow-batch device, whi...

متن کامل

Instrumentation and Automated Photometric Titration Procedure for Total Acidity Determination in Red Wine Employing a Multicommuted Flow System

An automated procedure for photometric titration of red wine and associated instrumentation is described. The procedure was based on the flow-batch approach implemented employing multicommutation. The photometric detection was carried out using a homemade LED-based photometer. The mixing device, LED, and photodetector were attached to the titration chamber in order to form a compact and small-s...

متن کامل

Development of a Low Cost and Safe PIV for Mean Flow Velocity and Reynolds Stress Measurements

In this study, a white light particle image velocimetry (WL PIV) system which employs a light sheet generated with a flash was used. The system was developed in order to provide a cost-efficient and safe alternative to laser systems while keeping the accuracy limits required for hydraulic model tests. To investigate the accuracy of WL PIV method under different flow conditions, experiments were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Automated Methods & Management in Chemistry

دوره 2006  شماره 

صفحات  -

تاریخ انتشار 2006