Body composition in renal transplant patients: bioimpedance analysis compared to isotope dilution, dual energy X-ray absorptiometry, and anthropometry.

نویسندگان

  • E C van den Ham
  • J P Kooman
  • M H Christiaans
  • F H Nieman
  • B K Van Kreel
  • G A Heidendal
  • J P Van Hooff
چکیده

Whether multifrequency bioelectrical impedance analysis (MF-BIA), a relatively new method for measuring body composition, is also applicable for accurate body composition measurements in renal transplant (RTx) patients is not known. Therefore, the use of MF-BIA is validated in 77 RTx patients with a stable renal function at least 2 yr posttransplantation. MF-BIA is compared to isotope dilution techniques for measurement of body water compartments, and to dual energy x-ray absorptiometry (DEXA) and anthropometry for measurement of fat and fat free mass. Finally, DEXA and anthropometry are compared to each other. Method agreement is assessed by intraclass correlation coefficients (ICC) and plotted by Bland and Altman analysis. MF-BIA significantly underestimates total body water (TBW, 0.7+/-2.1 L) and overestimates the extracellular water (ECW, 3.3+/-1.8 L) compared to isotope dilution; the ICC between both techniques is 0.943 for TBW and 0.846 for ECW. The percentage body fat (BF) measured by MF-BIA is significantly higher than both BF measured by DEXA (3.4+/-4.7%) or by anthropometry (5.5+/-5.2%). The ICC between MF-BIA and DEXA is 0.887 and between MF-BIA and anthropometry 0.856. BF measured by DEXA is significantly higher than BF measured by anthropometry (2.1+/-4.4%); their ICC is 0.913. In conclusion, MF-BIA seems to be suitable for measurement of TBW in RTx patients; however, method agreement between isotope dilution and MF-BIA for the measurement of ECW is not satisfactory. In the assessment of fat and fat free mass, the reliability of MF-BIA appears to be questionable. Method agreement between DEXA and anthropometry seems to be slightly better.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution.

BACKGROUND Current K-DOQI recommendations call for an assessment of dialysis adequacy that depends critically on an estimate of total body water (TBW). Such estimates are problematic in children since the range of patient size is large, and often formulas derived in normals are not validated in end-stage renal disease. Gold standard methods of TBW measurement, such as deuterium dilution ((2)H(2...

متن کامل

Development of methods for body composition studies.

This review is focused on experimental methods for determination of the composition of the human body, its organs and tissues. It summarizes the development and current status of fat determinations from body density, total body water determinations through the dilution technique, whole and partial body potassium measurements for body cell mass estimates, in vivo neutron activation analysis for ...

متن کامل

Assessment of body composition in Indian adults: comparison between dual-energy X-ray absorptiometry and isotope dilution technique

Dual-energy X-ray absorptiometry (DXA) and isotope dilution technique have been used as reference methods to validate the estimates of body composition by simple field techniques; however, very few studies have compared these two methods. We compared the estimates of body composition by DXA and isotope dilution (18O) technique in apparently healthy Indian men and women (aged 19-70 years, n 152,...

متن کامل

Four-component model of body composition in chronic renal failure comprising dual-energy X-ray absorptiometry and measurement of total body water by deuterium oxide dilution.

1. Assessment of nutrition in patients with chronic renal failure by body composition measurement techniques may be affected by variable hydration. 2. This study aimed to derive a four-component model of body composition (consisting of fat, protein, total body water and body mineral) from a combination of dual-energy X-ray absorptiometry and total body water measured by deuterium oxide dilution...

متن کامل

Nutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.

Protein energy malnutrition is common among persons with ESRD and contributes substantially to morbidity and mortality. The usual methods of nutritional assessment, such as anthropometry, can be misleading because of altered tissue hydration. Bioelectrical impedance analysis (BIA) has been recommended by some as a practical nutritional assessment tool but has not been validated in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 10 5  شماره 

صفحات  -

تاریخ انتشار 1999