T Wave Safety Margin during the Process of ICD Implantation As a Novel Predictor of T Wave Oversensing

نویسندگان

  • Ya-Xun Sun
  • Jing Gao
  • Chen-Yang Jiang
  • Yu-Mei Xue
  • Yi-Zhou Xu
  • Gang Liu
  • Ji-Hong Guo
  • Xia Sheng
  • Yang Ye
  • Hong He
  • Yun-Tao Zhao
  • Hector Barajas-Martinez
  • Guo-Sheng Fu
  • Dan Hu
چکیده

Introduction: T wave oversensing (TWOS) is a major drawback of implantable cardioverter defibrillator (ICD) and data on predictors of TWOS in ICD is limited. We aimed to calculate a novel index of T wave safety margin (TWSM) and assess its potential for evaluating TWOS during the procedure of ICD implantation. Methods and Results: Thirty-two consecutive patients with ICD implantation were enrolled. During each procedure of ICD implantation, different ICD generators were connected to implanted sensing lead through active-fixation leads and bridging cables. R and T wave amplitudes were measured on ICD printouts according to the gain. The ICDs were programed to the most sensitive settings to reveal possible TWOS. A novel index TWSM was calculated according to the corresponding sensing algorithm of ICD. There was discrepancy of R wave amplitudes measured by different ICDs (P < 0.01). In Fortify and Teligen ICDs, T wave amplitudes showed no difference (P > 0.05) and TWSMs were sufficiently high (post sensing: 13.0 ± 7.6 and 28.3 ± 16.5, respectively, post pacing: 5.0 ± 2.2 and 4.6 ± 0.9, respectively). In nine patients with 10 TWOS episodes detected during the procedure of ICD implantation, generators with the highest TWSM were chosen. Only one TWOS episode during pacing was recorded during the 25 ± 7 mo follow-up period. Conclusions: We first propose the index of TWSM during ICD implantation as a potentially efficient predictor for TWOS. Evaluation of TWSM might help to reduce TWOS episodes in patients with high risk of TWOS. Prospective studies are warranted to validate this index and its potential to reduce TWOS episodes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T Wave Oversensing

T wave oversensing is quite a familiar phenomenon to anyone who has watched cardiac monitors for sufficiently long periods in the coronary care unit. The counter starts giving dual beeps for every cardiac cycle instead of one. If it persists during several cycles, the displayed rate goes up and the monitor sounds an alarm indicating 'tachycardia'. This occurs usually when the monitoring lead di...

متن کامل

T wave oversensing and low percentage of biventricular pacing in cardiac resynchronization therapy.

The success of cardiac resynchronization therapy (CRT) depends on a high percentage of ventricular pacing. We present the electrocardiography and electrograms of a patient who underwent an implantable cardioverter-defibrillator (ICD) with CRT implantation showing a low percentage of ventricular pacing as a result of T wave oversensing of paced QRS. The patient showed no clinical improvement. We...

متن کامل

Hyperglycemia-Induced T-Wave Oversensing as a Cause of Cardiac Resynchronization Therapy (CRT) Failure

T-wave oversensing occurs when the counter starts giving dual beeps for every cardiac cycle instead of one. This usually happens when the monitoring lead displays a tall T wave, which is also sharp. R wave sensing algorithms of the devices do not sense T wave because the slow rate of the T wave is much less than that of the R wave. But the slow rate of T waves may change with time and also beca...

متن کامل

T-wave oversensing in patients with Brugada syndrome: true bipolar versus integrated bipolar implantable cardioverter defibrillator leads: multicenter retrospective study.

BACKGROUND It is thought that dedicated bipolar are more susceptible to T-wave oversensing when compared with integrated bipolar leads. This could be of extreme importance in patients with Brugada syndrome (BrS) because T-wave oversensing in this population is more frequent when compared with other implantable cardioverter defibrillator (ICD) recipients without BrS. We aimed to compare the inci...

متن کامل

T-wave oversensing during drug challenge test after subcutaneous implantable cardioverter-defibrillator implantation in a patient with Brugada syndrome

The subcutaneous implantable cardioverter-defibrillator (S-ICD) is an effective alternative to the conventional transvenous ICD (TV-ICD) system in patients that can be employed without the need for antitachycardia or antibradycardia pacing. Because the risk associated with a TV-ICD increases over time, populations in which there may be a preference for an S-ICD include younger patients, those w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017