Treatment of severe dialysis reactions with the AN69-ST membrane: biocompatibility does matter

نویسندگان

  • Luís Coentrão
  • Patrícia Martins
  • Ana Leblanc
  • Carmen Botelho
  • Berta Aguiar Carvalho
  • Manuel Pestana
چکیده

Dialysis reactions with biocompatible membranes are rare, and complement activation has been suggested to be a culprit. We report here a case of an incident haemodialysis patient with asthma disease who experienced severe adverse reactions late into dialysis session, with different synthetic membranes (FX 80, Fresenius; Polyflux 17L, Gambro; FX 10, Fresenius; BLS 512, Bellco-Sorin). After replacing the dialyser by the surface-treated AN69 membrane (Nephral ST 500, Hospal), the dialysis sessions became uneventful. The case reinforces the need for biocompatible dialysers with high permeability and adsorptive capacity in susceptible patients experiencing severe dialysis reactions with synthetic membranes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The AN69 ST haemodialysis membrane under conditions of two different extracorporeal circuit rinse protocols a comparison of thrombogenicity parameters.

BACKGROUND Thrombogenicity is an important parameter of haemodialysis (HD) membrane biocompatibility. The surface of the polyacrylonitrile AN69 ST membrane is coated with a polyethylenimine. This modification allows heparin adsorption. The binding of heparin to the membrane surface occurs during priming of the extracorporeal circuit (ECC) by rinsing it with saline and heparin. Our aims were to ...

متن کامل

Bradykinin is a mediator of anaphylactoid reactions during hemodialysis with AN69 membranes.

Anaphylactoid reactions (AR) are the most feared complications of hemodialysis. Recently, a high incidence of AR has been reported during dialysis with AN69 membranes in patients treated with ACE inhibitors. Plasma levels of C3a, histamine and bradykinin were measured in 12 patients at the onset of AR during dialysis with AN69. We also investigated bradykinin generation in 10 symptom-free patie...

متن کامل

Intestinal manifestations with a surface-treated AN69 membrane and ACEI during haemodialysis.

Sir, AN69-associated reactions in haemodialysed patients receiving angiotensin-converting enzyme inhibitors (ACEI) are well-documented [1]. The negatively charged AN69 membrane is thought to activate the bradykinin system. Moreover, ACEI reduces bradykinin inactivation. Surface-treated AN69 is considered to be safer in that regard. To our knowledge, only one case of anaphylactoid reaction induc...

متن کامل

Role of bradykinin in anaphylactoid reactions during hemodialysis with AN69 dialyzers.

In vitro experiments have related anaphylactoid reactions in patients treated with angiotensin-converting enzyme (ACE) inhibitors during dialysis with AN69 membranes to excessive bradykinin generation using this negatively charged dialysis membrane. In the present clinical trial plasma bradykinin levels were followed during the early phase of dialysis in 10 patients, not being treated with ACE ...

متن کامل

Acute haemodialysis membrane-associated reactions.

Acute reactions to the haemodialysis membrane have been reported as early as 1975 [1]. Because their severity is usually mild, their frequency is probably widely underestimated. However, these reactions may occasionally be life-threatening [2]. The aetiological mechanisms of these reactions are multiple, the best characterized being allergy to ethylene oxide and combined exposure to the polyacr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010