Residual-based Localization and Quantification of Peaks in X-ray Diffractograms
نویسندگان
چکیده
We consider data consisting of photon counts of diffracted x-ray radiation as a function of the angle of diffraction. The problem is to determine the positions, powers and shapes of the relevant peaks. An additional difficulty is that the power of the peaks is to be measured from a baseline which itself must be identified. Most methods of de-noising data of this kind do not explicitly take into account the modality of the final estimate. The residual-based procedure we propose uses the so-called taut string method, which minimizes the number of peaks subject to a tube constraint on the integrated data. The baseline is identified by combining the result of the taut string with an estimate of the first derivative of the baseline obtained using a weighted smoothing spline. Finally, each individual peak is expressed as the finite sum of kernels chosen from a parametric family.
منابع مشابه
TWO-STAGE METHOD FOR DAMAGE LOCALIZATION AND QUANTIFICATION IN HIGH-RISE SHEAR FRAMES BASED ON THE FIRST MODE SHAPE SLOPE
In this paper, a two-stage method for damage detection and estimation in tall shear frames is presented. This method is based on the first mode shape of a shear frame. We demonstrate that the first mode shape slope is very sensitive to the story stiffness. Thus, at the first stage, by using the grey system theory on the first mode shape slope, damage locations are identified in shear frames. Da...
متن کاملDetermination of cristobalite phase content in ceramic cores using various X-ray quantitative phase analysis methods
The aim of this research is to investigate different X-ray based quantitative phase analysis methods for determination of cristobalite phase content in ceramic cores. For this purpose, four popular routes including peak absolute intensity method, relative intensity ratio method, direct or calibration method and internal standard (or Alexander-Klug) method have been chosen. Some control samples ...
متن کاملHydroxyapatite coatings grown by pulsed laser deposition with a beam of 355 nm wavelength
Calcium phosphate coatings, obtained at different deposition rates by pulsed laser deposition with a Nd:YAG laser beam of 355 nm wavelength, were studied. The deposition rate was changed from 0.043 to 1.16 Å/shot by modification of only the ablated area, maintaining the local fluence constant to perform the ablation process in similar local conditions. Characterization of the coatings was perfo...
متن کاملInfluence of Residual Stress on Fatigue Life of Hot Forged and Shot Blasted Steel Components
Hot forging is a common manufacturing process for the production of large quantities of engineering components. Residual stresses are developed in forged components as a result of various aspects of the manufacturing process, including subsequent cooling, and heat treatment. Residual stresses can significantly affect the deformation and fatigue failure of materials. Hot forged EN15R steel bars ...
متن کاملThoracic Mass Nature Determination; What Modality Is Better in Pediatric Age?
Background The first step in assessing thoracic lesions is chest X-ray, but the optional imaging procedure for the final diagnosis is controversial. We aimed to examine the diagnostic accuracy of imaging modalities in pediatric thoracic masses. <em...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008