A focal-spot diagnostic for on-shot characterization of high-energy petawatt lasers.

نویسندگان

  • J Bromage
  • S-W Bahk
  • D Irwin
  • J Kwiatkowski
  • A Pruyne
  • M Millecchia
  • M Moore
  • J D Zuegel
چکیده

An on-shot focal-spot diagnostic for characterizing high-energy, petawatt-class laser systems is presented. Accurate measurements at full energy are demonstrated using high-resolution wavefront sensing in combination with techniques to calibrate on-shot measurements with low-power sample beams. Results are shown for full-energy activation shots of the OMEGA EP Laser System.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of the dynamic wavefront control of a pulsed kilojoule/nanosecond-petawatt laser facility.

The wavefront aberrations in a large-scale, flash-lamp-pumped, high-energy, high-power glass laser system can degrade considerably the quality of the final focal spot, and limit severely the repetition rate. The various aberrations induced on the Laboratoire pour l'Utilisation des Lasers Intenses (LULI), laser facility (LULI2000) throughout the amplification are identified and analyzed in detai...

متن کامل

Repetitive petawatt-class laser with near-diffraction-limited focal spot and transform-limited pulse duration

A repetitive petawatt-class Ti:sapphire laser system operating with high spatial and temporal beam quality is demonstrated. Maximum pulse energy of 30 J is obtained via five multi-pass amplification stages. Closed-loop feedback control systems in the temporal and spatial domains are used to yield Fourier-transform-limited pulse duration (33.7 fs), and diffraction-limited focal spot sizes (with ...

متن کامل

Wave-front correction of femtosecond terawatt lasers by deformable mirrors.

Wave-front correction and focal spot improvement of femtosecond laser beams have been achieved, for the first time to our knowledge, with a deformable mirror with an on-line single-shot three-wave lateral shearing interferometer diagnostic. Wave-front distortions of a 100-fs laser that are due to third-order nonlinear effects have been compensated for. This technique, which permits correction i...

متن کامل

A Single-Shot-Autocorrelator with 60-dB Dynamic Range

The development of single-shot, high-dynamic-range temporal measurement devices has become necessary for characterizing high-energy petawatt laser pulses. Because of the low repetition rate of such systems, no device offers high-dynamic-range measurements in a single-shot mode. In addition, investigating the unexpected temporal behavior of pulses amplified by new techniques such as analyzed in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 16 21  شماره 

صفحات  -

تاریخ انتشار 2008