Biomechanical comparison of interference screws and combination screw and sheath devices for soft tissue anterior cruciate ligament reconstruction on the tibial side.

نویسندگان

  • Cathrine Aga
  • Matthew T Rasmussen
  • Sean D Smith
  • Kyle S Jansson
  • Robert F LaPrade
  • Lars Engebretsen
  • Coen A Wijdicks
چکیده

BACKGROUND The tibial fixation site has been reported to be the weakest point in anterior cruciate ligament (ACL) reconstructions. Numerous interference screws and combination screw and sheath devices are available for soft tissue fixation, and a biomechanical comparison of these devices is necessary. HYPOTHESIS Combination screw and sheath devices would provide superior soft tissue fixation properties compared with interference screws in a porcine model. STUDY DESIGN Controlled laboratory study. METHODS Eight different intratunnel tibial soft tissue fixation devices were biomechanically tested in a porcine model with bovine tendons, with 10 specimens per group. The soft tissue fixation devices included 3 interference screws-the Bio-Interference Screw, BIOSURE PK, and RCI Screw-and 5 combination screw and sheath devices (combination devices)-the AperFix II, BIOSURE SYNC, ExoShape, GraftBolt, and INTRAFIX. The specimens were subjected to cyclic (1000 cycles, 50-250 N, 0.5 Hz) and pull-to-failure loading (50 mm/min) with a dynamic tensile testing machine. Ultimate failure load (N), cyclic displacement (mm), pull-out stiffness (N/mm), displacement at failure (mm), load at 3 mm displacement (N), and mechanism of failure were recorded. RESULTS The ultimate failure loads were highest for the GraftBolt (1136 ± 115.6 N), followed by the INTRAFIX (1127 ± 155.0 N), AperFix II (1122 ± 182.9 N), BIOSURE PK (990.8 ± 182.1 N), Bio-Interference Screw (973.3 ± 95.82 N), BIOSURE SYNC (829.5 ± 172.4 N), RCI Screw (817.7 ± 113.9 N), and ExoShape (814.7 ± 178.8 N). The AperFix II, GraftBolt, and INTRAFIX devices were significantly stronger than the BIOSURE SYNC, RCI Screw, and ExoShape. Although the 3 strongest devices were combination screw and sheath devices, no significant differences were observed between the ultimate failure strengths of the screw and combination devices when compared as groups. The least amount of cyclic displacement after 1000 cycles was observed for the GraftBolt (1.38 ± 0.27 mm), followed by the AperFix II (1.58 ± 0.21 mm), Bio-Interference Screw (1.61 ± 0.22 mm), INTRAFIX (1.63 ± 0.15 mm), ExoShape (1.68 ± 0.30 mm), BIOSURE PK (1.72 ± 0.29 mm), BIOSURE SYNC (1.92 ± 0.59 mm), and RCI Screw (1.97 ± 0.39 mm). The GraftBolt allowed significantly less displacement than did the BIOSURE SYNC and RCI Screw. Similarly, no significant differences were observed between the cyclic displacements of the screws and combination devices when compared as groups. CONCLUSION The combination screw and sheath devices did not provide superior soft tissue fixation properties compared with the interference screws alone in a porcine model. Although the highest ultimate failure loads and least amounts of cyclic displacement were observed for combination devices, group comparisons of screw and combination devices did not result in any significant differences for ultimate failure load and cyclic displacement. CLINICAL RELEVANCE It is important to consider that these results represent device performance in an in vitro animal model and are not directly transferrable to an in vivo clinical situation. The combination of a sheath and screw did not consistently result in improved fixation characteristics compared with interference screw fixation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Soft Tissue Anterior Cruciate Ligament Reconstruction on the Tibial Side Biomechanical Comparison of Interference Screws and Combination Screw and Sheath Devices

http://ajs.sagepub.com/content/41/4/841 The online version of this article can be found at: DOI: 10.1177/0363546512474968 2013 41: 841 originally published online February 12, 2013 Am J Sports Med Coen A. Wijdicks Cathrine Aga, Matthew T. Rasmussen, Sean D. Smith, Kyle S. Jansson, Robert F. LaPrade, Lars Engebretsen and Soft Tissue Anterior Cruciate Ligament Reconstruction on the Tibial Side Bi...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Functional Outcome Following Arthroscopic ACL Reconstruction with Rigid Fix: A Retrospective Observational Study

  Background: No uniform consensus exists to decide type of fixation for arthroscopic anterior cruciate ligament reconstruction. Hypothsis: There is similar functional outcome after rigid fix compared to other methods of fixation which has been published. Study design: Retrospective observational study. Methods: A total of 50 patients underwent arthroscopic anterior cruciate ligament reconstruc...

متن کامل

Tibial fixation of anterior cruciate ligament allograft tendons: comparison of 1-, 2-, and 4-stranded constructs.

BACKGROUND In sum, 1-, 2-, and 4-stranded allografts are used for soft tissue anterior cruciate ligament reconstruction; however, the fixation properties of fixation devices are not well assessed. HYPOTHESIS There are no differences in the biomechanical characteristics of 1 (Achilles)-, 2 (posterior tibialis)-, and 4 (semitendinosus)-stranded allograft tibial fixation. STUDY DESIGN Controll...

متن کامل

Biomechanical comparison of hamstring and patellar tendon graft anterior cruciate ligament reconstruction techniques: The impact of fixation level and fixation method under cyclic loading.

PURPOSE To mechanically test different reconstruction techniques of the anterior cruciate ligament (ACL) under incremental cyclic loading and to evaluate the impact of the level and method of graft fixation on tensile properties of each technique. TYPE OF STUDY In vitro biomechanical study. METHODS Four hamstring and 1 patellar tendon reconstruction techniques were performed on 40 young to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 41 4  شماره 

صفحات  -