The susceptibility of IMRT dose distributions to intrafraction organ motion: An investigation into smoothing filters derived from four dimensional computed tomography data.

نویسندگان

  • Catherine Coolens
  • Phil M Evans
  • Joao Seco
  • Steve Webb
  • Jane M Blackall
  • Eike Rietzel
  • George T Y Chen
چکیده

This study investigated the sensitivity of static planning of intensity-modulated beams (IMBs) to intrafraction deformable organ motion and assessed whether smoothing of the IMBs at the treatment-planning stage can reduce this sensitivity. The study was performed with a 4D computed tomography (CT) data set for an IMRT treatment of a patient with liver cancer. Fluence profiles obtained from inverse-planning calculations on a standard reference CT scan were redelivered on a CT scan from the 4D data set at a different part of the breathing cycle. The use of a nonrigid registration model on the 4D data set additionally enabled detailed analysis of the overall intrafraction motion effects on the IMRT delivery during free breathing. Smoothing filters were then applied to the beam profiles within the optimization process to investigate whether this could reduce the sensitivity of IMBs to intrafraction organ motion. In addition, optimal fluence profiles from calculations on each individual phase of the breathing cycle were averaged to mimic the convolution of a static dose distribution with a motion probability kernel and assess its usefulness. Results from nonrigid registrations of the CT scan data showed a maximum liver motion of 7mm in superior-inferior direction for this patient. Dose-volume histogram (DVH) comparison indicated a systematic shift when planning treatment on a motion-frozen, standard CT scan but delivering over a full breathing cycle. The ratio of the dose to 50% of the normal liver to 50% of the planning target volume (PTV) changed up to 28% between different phases. Smoothing beam profiles with a median-window filter did not overcome the substantial shift in dose due to a difference in breathing phase between planning and delivery of treatment. Averaging of optimal beam profiles at different phases of the breathing cycle mainly resulted in an increase in dose to the organs at risk (OAR) and did not seem beneficial to compensate for organ motion compared with using a large margin. Additionally, the results emphasized the need for 4D CT scans when aiming to reduce the internal margin (IM). Using only a single planning scan introduces a systematic shift in the dose distribution during delivery. Smoothing beam profiles either based on a single scan or over the different breathing phases was not beneficial for reducing this shift.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality assurance device for four‐dimensional IMRT or SBRT and respiratory gating using patient‐specific intrafraction motion kernels

Emerging technologies such as four-dimensional computed tomography (4D CT) and implanted beacons are expected to allow clinicians to accurately model intrafraction motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. In the case of intensity-modulated (IMRT) and stereotactic body radiation therapy (SBRT) delivery, clinicians must c...

متن کامل

The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study

Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...

متن کامل

Prostate Intrafraction Motion Assessed by Simultaneous Kv

PROSTATE INTRAFRACTION MOTION ASSESSED BY SIMULTANEOUS KV FLUOROSCOPY AT MV DELIVERY by JUSTUS D. ADAMSON August 2009 Co-Advisor: Dr. Qiuwen Wu Co-Advisor: Dr. Jay Burmeister Major: Medical Physics Degree: Doctor of Philosophy Purpose: To investigate the use of a gantry mounted kV imager for prostate intrafraction motion measurement during simultaneous dose delivery. Materials & Methods: We dev...

متن کامل

Evaluation of inter- and intrafraction organ motion during intensity modulated radiation therapy (IMRT) for localized prostate cancer measured by a newly developed on-board image-guided system.

PURPOSE To investigate prostatic organ motion at both setup and intrafraction using an onboard image-guided system. An intrafraction field-based repositioning method also was evaluated. MATERIALS AND METHODS A dual fluoroscopy with amorphous-silicon flat panel (DFFP) system was used for the three-dimensional registration of implanted markers in the prostate of eight organ-confined cancer pati...

متن کامل

Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation

Background:  This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation.  Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2006