[Evaluation of a new blood gas analysis system: RapidPoint 500(®)].
نویسندگان
چکیده
We present here evaluation of a new blood gas analysis system, RapidPoint 500(®) (Siemens Healthcare Diagnostics). The aim of this research was to compare the ergonomics and analytical performances of this analyser with those of the RapidLab 1265 for the following parameters: pH, partial oxygen pressure, partial carbon dioxide pressure, sodium, potassium, ionized calcium, lactate and the CO-oximetry parameters: hemoglobin, oxyhemoglobin, carboxyhemoglobin, methemoglobin, reduced hemoglobin, neonatal bilirubin; as well as with the Dimension Vista 500 results for chloride and glucose. The Valtec protocol, recommended by the French Society of Clinical Biology (SFBC), was used to analyze the study results. The experiment was carried out over a period of one month in the Department of medical biochemistry. One hundred sixty five samples from adult patients admitted to the ER or hospitalized in intensive care were tested. The RapidPoint 500(®) was highly satisfactory from an ergonomic point of view. Intra-and inter- assay coefficients of variation (CV) with the three control levels were below those recommended by the SFBC for all parameters, and the comparative study gave coefficients of determination higher than 0.91. Taken together, the RapidPoint 500(®) appears fully satisfactory in terms of ergonomics and analytical performance.
منابع مشابه
Point-of-Care Versus Central Laboratory Measurements of Hemoglobin, Hematocrit, Glucose, Bicarbonate and Electrolytes: A Prospective Observational Study in Critically Ill Patients
INTRODUCTION Rapid detection of abnormal biological values using point-of-care (POC) testing allows clinicians to promptly initiate therapy; however, there are concerns regarding the reliability of POC measurements. We investigated the agreement between the latest generation blood gas analyzer and central laboratory measurements of electrolytes, bicarbonate, hemoglobin, hematocrit, and glucose....
متن کاملDetermination of reference intervals and comparison of venous blood gas parameters using a standard and nonstandard collection method in 51 dogs.
INTRODUCTION The aim of this study was to determine reference intervals (RI) for venous blood parameters determined with the RAPIDPoint 500 (RP500) blood gas analyzer using blood gas syringes (BGS) and to determine whether immediate analysis of venous blood collected into lithium heparin (LH) tubes can replace anaerobic blood sampling into BGS. The null hypothesis was that canine venous blood s...
متن کاملin press - uncorrected proof Pseudohypocalcemia caused by perchlorate ( Irenat )
Background: Blood gas analysis (BGA), including measurement of ionized calcium, is performed routinely in patients with end stage renal disease on renal replacement therapy, especially when using citrate for regional anticoagulation. After installation of a new blood gas analyzer (RAPIDpoint 405; BGA), we observed lower ionized calcium concentrations in a few patients without signs of hypocalce...
متن کاملQuantitative evaluation of the domino effects of the explosion caused by the CNG fuel station using consequence modeling and GIS
Introduction: compressed natural gas stations are one of the most critical and dangerous urban land uses and should be highly regarded. The domino effects of accidents are essential concepts in urban areas. The present study aims to analyze explosive domino accidents at compressed natural gas stations (CNG). Modeling the consequence in fuel stations can minimize the likelihood of a crisis and l...
متن کاملAssessment of a continuous blood gas monitoring system in animals during circulatory stress
BACKGROUND The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI) in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions METHODS Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min), vasoconstriction (Arginine-vasopressin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annales de biologie clinique
دوره 71 3 شماره
صفحات -
تاریخ انتشار 2013