Calillary Pressure Curve Measurement Using a Single-moderate-speed Centrifuge and Quantitative Magnetic Resonance Imaging

نویسندگان

  • Quan Chen
  • Bruce J. Balcom
چکیده

For traditional centrifugal capillary pressure curve measurements, a short core plug is often employed. The capillary pressure is assumed to be zero at the outflow boundary of the core. The traditional experiments are time consuming. Measurement of the full capillary pressure curve often requires 7 to10 different centrifuge speeds, thus requiring one day to several days for measurement. Different approximate solutions may be employed to deduce the capillary pressure curve from experimental data of average saturation and the corresponding rotational speed. In the current work, we propose a new method to measure the capillary pressure curve using a single-moderate-speed centrifuge experiment and one dimensional centric scan SPRITE (Single-Point Ramped Imaging with T1 Enhancement) magnetic resonance imaging (MRI) technique for long rock samples. As a pure phase encoding quantitative MRI technique, centric scan SPRITE offers unique advantages in the measurement of spatially resolved fluid saturation in rocks. The proposed method is rapid and accurate. Because the new method uses a long core to directly measure a large range of saturation distributions along the length of the core, at a single moderate centrifuge speed, this process will be much faster than a traditional measurement. There is no requirement for an approximate solution; the capillary pressure curve is directly determined by the measured saturation profile. Long cores can be employed, which leads to a smaller radial effect than short core plugs. Since a moderate centrifuge speed is employed, the effect of gravity will be very small and the outlet boundary condition of the core plug can be satisfied. A comparison of capillary pressure curves obtained by a single-speed centrifuge and SPRITE MRI with mercury intrusion methods yields remarkably consistent results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracting Pore Throat Size and Relative Permeability from Mri Based Capillary Pressure Curves

Capillary pressure (Pc) curves acquired using the Magnetic Resonance Imaging (MRI) technique, call GIT-CAP, have 70-100 data points. This extra data, when compared with traditional porous plate or centrifuge techniques, allows for the interpretation of more information from the Pc curve. In particular, the pore throat size and relative permeability can be extracted. The pore throat size can be ...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Comparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei

Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...

متن کامل

A Single-shot Method for Determining Drainage and Imbibition Capillary Pressure Curves

A single-shot method to determine the capillary pressure curve employed a single rotational velocity centrifugation experiment and one-dimensional Centric Scan SPRITE (single-point ramped imaging with T1 enhancement) MRI (magnetic resonance imaging) to determine the fluid saturation distribution, S(r), along the length (r) of the core. A full capillary pressure curve can be directly determined ...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...