Transfer Function of Transformer Winding for Frequency Response Analysis Based on Traveling Wave Theory

نویسندگان

  • A. Shintemirov
  • Q. H. Wu
چکیده

This paper presents an improved model of uniform transformer winding for frequency response analysis (FRA), based on traveling wave theory. The accurate representation of the losses and detailed consideration of measurement chains are the main features of the model. The transfer function expression of the transformer winding and equivalent distributed-parameter circuit for FRA have been derived and upon which numerical simulation has been performed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Impulse Wave and Sweep Frequency Response Analysis Methods for Diagnosis of Transformer Winding Faults

Monitoring of winding faults is the most important item used to determine the maintenance status of a transformer. Commonly used methods for winding-fault diagnosis require the transformer to exit operation before testing and an external exciting signal, whether the transformer is malfunctioning or not. However, if an overvoltage signal can be regarded as a broadband excitation source for fault...

متن کامل

Power Auto-transformer Mechanical Faults Diagnosis ‎Using Finite Element based FRA

Frequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in...

متن کامل

Efficiency Improvement of the Flyback Converter Based on High Frequency Transformer Winding Rearrangement

In this paper, a novel method for loss reduction and efficiency optimization of the high frequency flyback transformers is proposed based on rearrangement of the windings. According to detailed analysis of the high frequency flyback transformer using FEM technique, a novel and simple approach for its design improvement and loss reduction is introduced. It is shown that leakage flux scattering i...

متن کامل

A Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum

Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...

متن کامل

بکارگیری مدار معادل مشروح توسعه‌یافته در ابعاد بزرگ برای مطالعه حالت گذرای ترانسفورماتور

In this paper, frequency response analysis (FRA) of transformer based on the detailed model of the transformer windings, is investigated. The determination of the detailed model parameters, which can be considered as a large scale model, is  a complex task. To overcome this problem, a heuristic method is presented in this paper. This method is applied to a large scale detailed model with n...