Electrochemical enzyme immunoassay for phenytoin by flow-injection analysis incorporating a redox coupling agent.

نویسندگان

  • H T Tang
  • H B Halsall
  • W R Heineman
چکیده

Using phenytoin as a model analyte, we demonstrate an electrochemical enzyme immunoassay based on flow-injection analysis and incorporating 2,6-dichloroindophenol (DCIP) as a redox coupling agent. DCIP reacts with NADH to form NAD+ and DCIPH2, the reduced form of the coupling agent. The production of DCIPH2 is monitored at +250 mV vs Ag/AgCl. This low applied potential improves selectivity in the biological matrix, differentiating against components that are oxidizable at the more-positive potentials required for direct electrochemical detection of NADH. The kinetics-based assay also eliminates other common interferences, mainly from ascorbic acid and glutathione. This system does not require precolumns or analytical columns for isolation of the NADH response. Good agreement with a routine clinical laboratory procedure for phenytoin is obtained for clinical samples (r = 0.95), illustrating the feasibility of such an approach.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Immunoassay Based on Sequential Injection Using Microbeads

A flow immunoassay based on a combined technique of the sequential injection with the beads injection using magnetic microbeads immobilized with antigen or antibody is described. A methodology of the present immunoassay based on chemiluminescence and electrochemical detection and its application to the determination of vitelloginin (Vg) and anionic surfactant, linear alkylbenzene sulfonate (LAS...

متن کامل

An interference-free and rapid electrochemical lateral-flow immunoassay for one-step ultrasensitive detection with serum.

Point-of-care testing (POCT) of biomarkers in clinical samples is of great importance for rapid and cost-effective diagnosis. However, it is extremely challenging to develop an electrochemical POCT technique retaining both ultrasensitivity and simplicity. We report an interference-free electrochemical lateral-flow immunoassay that enables one-step ultrasensitive detection with serum. The electr...

متن کامل

Recent Electrochemical and Optical Sensors in Flow-Based Analysis

Some recent analytical sensors based on electrochemical and optical detection coupled with different flow techniques have been chosen in this overview. A brief description of fundamental concepts and applications of each flow technique, such as flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (M...

متن کامل

Competitive heterogeneous enzyme immunoassay for theophylline by flow-injection analysis with electrochemical detection of p-aminophenol.

A competitive enzyme-linked immunoabsorbent assay based on the flow-injection amperometric detection of p-aminophenol has been investigated with use of the materials and general procedure of a commercial kit for the determination of theophylline in human serum. The antibody is immobilized on glass beads, and the enzyme label is alkaline phosphatase (EC 3.1.3.1). The high currents generated duri...

متن کامل

Heterogeneous enzyme immunoassay of alpha-fetoprotein in maternal serum by flow-injection amperometric detection of 4-aminophenol.

A sandwich-type heterogeneous enzyme immunoassay with flow-injection analysis for alpha-fetoprotein (AFP) in human serum has been developed. 4-Aminophenol, the product of enzymatic reaction, is detected amperometrically. The interassay CV for this electrochemical enzyme immunoassay was less than 8.2%, with a minimum detection limit for AFP of 0.163 micrograms/L. The calibration curve had a line...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 1991