A fluorescence lifetime-based fibre-optic glucose sensor using glucose/galactose-binding protein.
نویسندگان
چکیده
Alternative, non-electrochemistry-based technologies for continuous glucose monitoring are needed for eventual use in diabetes mellitus. As part of a programme investigating fluorescent glucose sensors, we have developed fibre-optic biosensors using glucose/galactose binding protein (GBP) labelled with the environmentally sensitive fluorophore, Badan. GBP-Badan was attached via an oligohistidine-tag to the surface of Ni-nitrilotriacetic acid (NTA)-functionalized agarose or polystyrene beads. Fluorescence lifetime increased in response to glucose, observed by fluorescence lifetime imaging microscopy of the GBP-Badan-beads. Either GBP-Badan agarose or polystyrene beads were loaded into a porous chamber at the end of a multimode optical fibre. Fluorescence lifetime responses were recorded using pulsed laser excitation, high speed photodiode detection and time-correlated single-photon counting. The maximal response was at 100 mM glucose with an apparent K(d) of 13 mM (agarose) and 20 mM (polystyrene), and good working-day stability was demonstrated. We conclude that fluorescence lifetime fibre-optic glucose sensors based on GBP-Badan are suitable for development as clinical glucose monitors.
منابع مشابه
Fluorescence intensity- and lifetime-based glucose sensing using glucose/galactose-binding protein.
We review progress in our laboratories toward developing in vivo glucose sensors for diabetes that are based on fluorescence labeling of glucose/galactose-binding protein. Measurement strategies have included both monitoring glucose-induced changes in fluorescence resonance energy transfer and labeling with the environmentally sensitive fluorophore, badan. Measuring fluorescence lifetime rather...
متن کاملFluorescence resonance energy transfer glucose sensor from site-specific dual labeling of glucose/galactose binding protein using ligand protection.
BACKGROUND Site-selective modification of proteins at two separate locations using two different reagents is highly desirable for biosensor applications employing fluorescence resonance energy transfer (FRET), but few strategies are available for such modification. To address this challenge, sequential selective modification of two cysteines in glucose/galactose binding protein (GGBP) was demon...
متن کاملA fiber optic sensor for measuring glucose in aqueous solutions
In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...
متن کاملFluorescence lifetime imaging microscopy of intracellular glucose dynamics.
BACKGROUND One of the major hurdles in studying diabetes pathophysiology is the lack of adequate methodology that allows for direct and real-time determination of glucose transport and metabolism in cells and tissues. In this article, we present a new methodology that adopts frequency-domain fluorescence lifetime imaging microscopy (FD-FLIM) to visualize and quantify the dynamics of intracellul...
متن کاملFiber-optic glucose biosensor based on glucose oxidase (GOD) immobilised in a silica gel matrix
In this paper, we report results obtained from a biosensor comprised of a monolithic silica sol–gel entrapping glucose oxidase (GOD) as sensing element coupled to a fibre-optic transducer element. GOD intrinsic fluorescence spectra were analysed in the UV and visible region in presence of different glucose concentrations, and the corresponding calibration curves were obtained. In addition, time...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 136 5 شماره
صفحات -
تاریخ انتشار 2011