Indoor air quality in Portuguese archives: a snapshot on exposure levels.
نویسندگان
چکیده
Indoor air quality recently entered legislation in Portugal. Several parameters must be evaluated and kept within limits in order to obtain a certification for air quality and energy consumption. Certification parameters were analyzed in two Portuguese archives in order to assess indoor air quality both for people attending or working on these premises and for maintenance of a written heritage that must be retained for future generations. Carbon monoxide (CO) and carbon dioxide (CO₂), formaldehyde, and fungal counts were kept within stipulated limits. Relative humidity (RH), volatile organic compounds (VOC), particulate matter (PM₁₀), and ozone (O₃) showed values above legislated levels and justified the implementation of corrective measures. In terms of conservation, studies on the limit values are still needed, but according to the available international guidelines, some of the analyzed parameters such as PM₁₀, O₃, and RH were also above desirable values. Corrective measures were proposed to these institutions. Although this study was only of a short duration, it proved valuable in assessing potential eventual problems and constitutes the first Portuguese indoor air quality assessment taking into consideration both aspects of an archive such as human health and heritage safekeeping.
منابع مشابه
بررسی ارتباط بین غلظت ذرات معلق در هوای داخل بیمارستان کودکان تهران و هوای آزاد اطراف آن در سال 1386
Background and Objectives: In recent years exposure to fine airborne particles has been identified as an important factor affecting human health. Epidemiological studies have showed that the aerosol laden air can be an agent for microorganisms’ dispersion. Ignoring internal sources, ambient air quality significantly affects indoor air quality. Since people spend most of their times in the indoo...
متن کاملبررسی آلاینده های شاخص هوای داخل و خارج منازل مسکونی شهری
Background and purpose: Indoor air pollution in developing countries is considered as one of the main problems in healthcare. This study aimed at investigating the levels of indoor/outdoor air pollutants in Khorramabad during autumn and winter 2012. Materials and methods: In a cross-sectional study, nine gas concentrations and particulate pollutants were measured using air pollution measuring ...
متن کاملAssessment of VOCs, PM10, and Formaldehyde Exposure in the Hair Salons of South Korea
Introduction: In hair salons, workers and customers are exposed to high concentrations of several chemical compounds used during the working environment. Volatile Organic Compounds (VOCs), particulate matter (PM10), nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), and formaldehyde are the major chemicals that alter the indoor air quality. This study aimed to assess the indoor...
متن کاملIndoor air quality monitoring in urban areas using Smart Sensing Technology
Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...
متن کاملForecasting Human Exposure to Atmospheric Pollutants in Portugal
Air pollution has become one main environmental concern because of its known impact on human health. Aiming to inform the population about the air they are breathing several air quality modelling systems have been developed and tested allowing, nowadays, assessing and forecasting air pollution ambient levels in many countries. However, every day, one individual is exposed to different concentra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of toxicology and environmental health. Part A
دوره 75 22-23 شماره
صفحات -
تاریخ انتشار 2012