Postpartum determination of umbilical artery blood gases: effect of time and temperature.
نویسندگان
چکیده
complete within 10 min, much shorter than the 90 min for the kinetic cadmium reduction method [13], 45 min for the enzymatic one-step assay [10], and 20 min for the enzymatic method of Moshage et al. [9]. Green et al. [12], by using a high-pressure reduction column coupled with a continuous-flow analyzer, reported a shorter reduction time (within 1 min), and an analysis rate of 30 samples per hour. Although our reduction time is longer, the analysis rate, considering the overall time spent on deproteinization, reduction, and measurement in a Hitachi 717 analyzer, amounts to .150 samples per hour. Recently, Yang et al. [11] described a very sensitive method for chemiluminescent detection of nitrate, but estimates for the analysis rate were 15–30 samples per hour. Moreover, the automated device by Green et al. [12] was specifically designed for analyzing nitrate concentrations and is not available to the majority of clinical chemistry laboratories. By contrast, Hitachi analyzers are widely used and allow simultaneous performance of other analyses. An additional advantage of this method is its low cost, because the cadmium may be regenerated and the reagents are cheaper than those used in enzymatic methods (nitrate reductase or b-NADPH). The semiautomated method described here responds in a quantitative linear fashion to nitrate within the range of 0.8 to 600 mmol/L, whereas the other methods are linear only up to 200–300 mmol/L. The detection limits and the within-run and between-day imprecisions for this method are similar to those reported in the other methods [9, 10, 12, 13]. Values reported for serum are similar to those documented by Moshage et al. [9]. We conclude that this semiautomated procedure provides an easy, less time-consuming, inexpensive, and reliable method of analysis for nitrate concentration in biological fluids, and is therefore suitable for routine performance in clinical chemistry laboratories.
منابع مشابه
The Effect of mode of delivery on the umbilical artery pH
Background: Abnormal umbilical cord pH can be indicated a distress imposed of newborn and can also be useful in determining the prognosis of the newborn. There are different views about the effect of the neonatal delivery method on the blood gas analysis of the umbilical artery. This study aimed to determine the effect of the method of delivery on umbilical artery pH. Methods: In this Cross ...
متن کاملP-247: To Evaluate The Oxytocin Effect on Maternal-Fetal Circulation during Termination of Pregnancy
Background: To evaluate the effect of oxytocin on blood circulation of fetus and uterus by Doppler ultrasound. Materials and Methods: Forty six pregnant women were assigned to receive for indication of delivery intravenous oxytocin. Doppler velocitometry before and after administration of oxytocin for umbilical,middle cerebral artery and uterine artery were performed, and Pulsatility index (PI)...
متن کاملReference intervals for 18 clinical chemistry analytes in fetal plasma samples between 18 and 40 weeks of pregnancy.
null hypothesis was that temperature had an effect on the test results. The data shown in Table 1 also reject this hypothesis and suggest that temperature alone does not affect the tested variables. There are almost no arguments against the value of umbilical artery blood gases analysis taken postpartum in cases indicated by ante-and intrapartum events. Because blood is a living tissue, it has ...
متن کاملThe relationship between umbilical artery blood gas analysis and Apgar scores in neonates
Extended Abstract Introduction and Background : in the first minutes of life it’s important to assess newborn condition very fast but effective and decide about medical intervention as needed. Umbilical artery blood gas analysis and Apgar scoring are the most common assessment systems which studies are trying to more sensitive and accurate way.in this study we compare Apgar scoring system an...
متن کاملبررسی تأثیر تجویز اکسیژن به مادر در مرحله دوم زایمان بر روی گازهای خون بند ناف
This study was conducted to assess the role of maternal oxygen administration during the second stage of labor on umbilical cord blood gas values. This study was done in Fatemieh hospital on 160 pregnant women who were admitted for vaginal delivery and had the inclusion criteria. A group ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 44 3 شماره
صفحات -
تاریخ انتشار 1998