Active positioning device for a perimodiolar cochlear electrode array
نویسندگان
چکیده
The authors report on an actuated positioning device for a cochlear prosthesis insertion procedure. The device consists of multiple high-aspect ratio fluidic actuator chambers integrated with a high-density silicon cochlear electrode array and manufactured in a taperedhelix form. Actuation chambers with cross-sectional sizes as small as 40 · 200 lm and lengths of 30 mm have been fabricated using flexible polymers. The device will allow for low-resistance basilar insertion of a stimulating electrode array into the cochlea providing for deep, perimodiolar position considered most beneficial for auditory nerve stimulation, while minimizing intracochlear trauma. Experimental measurements, FEA analysis, and modeling demonstrate a viable and appropriate actuation method for a cochlear implant procedure.
منابع مشابه
Perimodiolar electrode position: Effects on thresholds, comfort levels, impedance measurements, and neural response telemetry
OBJECTIVE: This multicenter study describes the effects of perimodiolar electrode position on 50 adult patients (31 with an implanted Nucleus 24 Contour perimodiolar hugging electrode array [Cochlear Limited, Lane Cove, NSW, Australia] and 19 with an implanted straight electrode array) with a severe-to-profound sensorineural hearing loss. MATERIALS AND METHODS: In all patients, intraoperative i...
متن کاملComparison of electrode position in the human cochlea using various perimodiolar electrode arrays.
OBJECTIVE This study was conducted to evaluate the insertion properties and intracochlear trajectories of three perimodiolar electrode array designs and to compare these designs with the standard Cochlear/Melbourne array. BACKGROUND Advantages to be expected of a perimodiolar electrode array include both a reduction in stimulus thresholds and an increase in dynamic range, resulting in a more ...
متن کاملRadiological and Histological Evaluation of Perimodular Electrodes: Impact on Cochlear Implant Development
Introduction: Different Perimodiolar electrodes were developed by many cochlear implant (CI) manufacturers in the past few years. Possible advantages are lower stimulation thresholds and a better channel separation. A position close to the modiolus can be facilitated by different means: preformed electrode shape (Nucleus ContourTM electrode, Cochlear Corp., Australia), additional positioning el...
متن کاملA Psychophysics experimental software to evaluate electrical pitch discrimination in Nucleus cochlear implanted patients
Multichannel electrode array design in cochlear implants has evolved into two major categories: straight and perimodiolar electrodes. When implanted, the former lies along the outer wall of the scala tympani, while the later are located closer to the modiolus, where the neural ends are. Therefore, a perimodiolar position of the electrode array could be expected to result in reduced stimulus thr...
متن کاملDevelopment and evaluation of the modiolar research array – multi-centre collaborative study in human temporal bones
OBJECTIVE Multi-centre collaborative study to develop and refine the design of a prototype thin perimodiolar cochlear implant electrode array and to assess feasibility for use in human subjects. STUDY DESIGN Multi-centre temporal bone insertion studies. MATERIALS AND METHODS The modiolar research array (MRA) is a thin pre-curved electrode that is held straight for initial insertion with an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004