Posterior spinal fusion using pedicle screws.
نویسندگان
چکیده
Few clinical studies have reported polyetheretherketone (PEEK) rod pedicle screw spinal instrumentation systems (CD-Horizon Legacy PEEK rods; Medtronic, Minneapolis, Minnesota). This article describes a clinical series of 52 patients who underwent posterior spinal fusion using the PEEK Rod System between 2007 and 2010. Of the 52 patients, 25 had degenerative disk disease, 10 had lateral recess stenosis, 6 had degenerative spondylolisthesis, 6 had lumbar spine vertebral fracture, 4 had combined lateral recess stenosis and degenerative spondylolisthesis, and 1 had an L5 giant cell tumor. Ten patients had 1-segment fusion, 29 had 2-segment fusion, and 13 had 3-segment fusion. Mean follow-up was 3 years (range, 1.5-4 years); no patient was lost to follow-up. Clinical evaluation was performed using the Oswestry Disability Index and a low back and leg visual analog pain scale. Imaging evaluation of fusion was performed with standard and dynamic radiographs. Complications were recorded. Mean Oswestry Disability Index scores improved from 76% preoperatively (range, 52%-90%) to 48% at 6 weeks postoperatively, and to 34%, 28%, and 30% at 3, 6, and 12 months postoperatively, respectively. Mean low back and leg pain improved from 8 and 9 points preoperatively, respectively, to 6 and 5 points immediately postoperatively, respectively, and to 2 points each thereafter. Imaging union of the arthrodesis was observed in 50 (96%) patients by 1-year follow-up. Two patients sustained screw breakage: 1 had painful loss of sagittal alignment of the lumbar spine and underwent revision spinal surgery with pedicle screws and titanium rods and the other had superficial wound infection and was treated with wound dressing changes and antibiotics for 6 weeks. No adjacent segment degeneration was observed in any patient until the time of this writing.
منابع مشابه
Comparison between posterior lumbar fusion with pedicle screws and posterior lumbar interbody fusion with pedicle screws in adult spondylolisthesis.
The purpose of this study was to compare patients with lumbar spondylolisthesis submitted to two different surgical approaches, and evaluate the results and outcomes in both groups. In a two-year period, 60 adult patients with lumbar spondylolisthesis, both isthmic and degenerative, were submitted to surgery at the Biocor Institute, Brazil. All patients were operated on by the same surgeon (FLR...
متن کاملThe quantitative assessment of contribution of risk factors to overstress at adjacent segments after lumbar fusion: removal of posterior ligaments, pedicle screws
Adjacent segment deterioration (ASD) is a serious sequela of spinal fusion surgery that has recently become much more widespread due to an increasing number of spinal fusions performed [1]. Moreover, previous studies [2] of potential risk factors for ASD have found that instrumentation, posterior lumbar interbody fusion, injury to the facet joint of the adjacent segment, fusion length, age, and...
متن کاملPosterior Spinal Reconstruction with Pedicle Screws, Multiple Iliac Screws and Wisconsin Spinal Wires in a Patient with Neurofibromatosis Scoliosis: A Case Report
A 54-year-old female with neurofibromatosis type 1 presented with progressing truncal shift owing to spinal deformity. On plain radiograph, the Cobb angle was 54 degree in coronal plane. Radiological examinations showed severe dystrophic change with dysplastic pedicles, bony scalloping, neural foraminal widening from dural ectasia. The patient underwent deformity correction and reconstruction s...
متن کاملBiomechanical Evaluation of a Standalone Lumbar Interbody Cage with Integrated Screws
INTRODUCTION: Spinal fusion techniques including anterior lumbar interbody fusion (ALIF) have been used to alleviate chronic low back pain and segmental instability. Supplemental fixation using pedicle screws, translaminar screws, facet screws, anterior plates or spinous process plates is often used to increase the stability of the ALIF construct to enhance fusion and prevent subsidence and mig...
متن کاملMini-open or percutaneous bilateral lumbar transfacet pedicle screw fixation: a technical note.
STUDY DESIGN Case report. OBJECTIVE To describe the technique used to place bilateral lumbar transfacet pedicle screws. SUMMARY OF BACKGROUND DATA Transfacet pedicle screw fixation is a growing alternative and biomechanically comparable with traditional pedicle screw fixation. There is no clear description of technique steps for placing transfacet pedicle screws available in the literature,...
متن کاملPositioning Performance of Power and Manual Drivers in Posterior Spinal Fusion Procedures
This work presents an analysis and comparison of the efficacy of two methods for pedicle screw placement during posterior spinal fusion surgery. A total of 100 screws (64 manual and 36 power driven), all placed utilizing a surgical navigation system, were analyzed and compared. Final screw placement was compared to initial surgical plans using the navigation system, and the final screw location...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 36 7 شماره
صفحات -
تاریخ انتشار 2013