Photoelastic Stress Analysis Surrounding Implant-Supported Prosthesis and Alveolar Ridge on Mandibular Overdentures
نویسندگان
چکیده
The purpose of this research was to evaluate the maximum stress around osseointegrated implants and alveolar ridge, in a mandible with left partial resection through a photoelastic mandibular model. The first group consisted of two implants: traditional model (T), implants placed in the position of both canines; fulcrum model (F), implants placed in the position of left canine CL and right lateral incisor LiR. Both models linked through a bar and clips. The second group was consisted of three implants, with implants placed in the position of both canines (CR and CL) and the right lateral incisor (LiR), which composed four groups: (1) model with 3 "O" rings, (2) model 2 ERAs, bar with clips, (3) model 2 ERAs bar without clips; (4) model "O" ring bar and ERA. An axial and an oblique load of 6.8 kgf was applied on a overdenture at the 1st Pm, 2nd Pm, and 1st M. Results showed that the area around the left canine (CL) was practically free of stress; the left lateral incisor (LiL) developed only small tensions, and low stress in all the other cases; the right canine tooth suffered the largest concentrations of stress, mainly with the ERA retention mechanism.
منابع مشابه
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملBiomechanical Analysis of Implant Assisted-Overdentures with Variations in the Attachments Systems
The aim of this study was to assess the stress patterns on the peri-implant zone and residual alveolar ridge in different overdenture attachment system designs by the photoelasticity method. Four attachments systems were tested: O-ring, ERA, Bar-clip, and Bar-clip/O-ring association. The prostheses were loaded with 100 N in five pre-determined points and the photoelastic model was evaluated by ...
متن کاملEffect of Abutment Height Difference on Stress Distribution in Mandibular Overdentures: A Three-Dimensional Finite Element Analysis
Background and Aim: Implant-supported overdentures are a treatment option for edentulous patients. One of the important factors in determining the prognosis of overdenture treatment is to control the distribution of stress in the implant-bone and attachment complex. This study assessed the effect of implant abutment height difference on stress distribution in mandibular overdentures. Materials...
متن کاملRitva Kuoppala Outcome of Implant - Supported Overdenture Treatment
The retention of a complete denture and the patient’s adaptation varies considerably among different individuals. Resorption of the edentulous alveolar ridge differs greatly and some patients need implant-retained overdentures to enable adequate retention of their prostheses. In some extreme cases it is necessary to increase the volume of the alveolar ridge with bone grafts. The aim of this stu...
متن کاملComparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2010 شماره
صفحات -
تاریخ انتشار 2010