Effect of phenols on the potentiometric response of a nitrate-ion-selective electrode.

نویسندگان

  • Walton J Cabrera
  • Marcela Urzúa
  • Hernán E Ríos
چکیده

The effect of phenols containing different electron-withdrawing substituents on the potentiometric responses of several liquid PVC membranes containing the complex trioctylmethylammonium-nitrate, TOMA(+)NO(3)(-), is analyzed. The results make it possible to separate these phenols into two groups; those phenols containing electron-releasing groups, which produce almost Nernstian slopes, and those containing electron-withdrawing substituents, which generate sub-Nernstian slopes. The highly negative standard free energy of transfer of the aryl phenolic group from water to a cationic polar head suggests that these phenols are mainly located in the membrane phase associated with TOMA(+) via a cation-pi interaction. It seems that the strength of this interaction, and hence of the nitrate dissociation, is affected by the presence of phenols in an extension which correlates well with the kind of phenol present in these membranes and, consequently, with the type of their potentiometric responses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Application of a dioxime-PVC electrode to potentiometric studies of Cr(III) ion

A PVC membrane Cr(III) ion selective electrode has been constructed using 2H-1,4-benzothioazine-2,3(4H)dione dioxime (BTD) as membrane carrier. The influence of membrane composition on the electroderesponse was studied. The electrode exhibits a Nernstian response over a Cr(III) concentration range of 1.0 x10 6 to 1.0>< 10-1 M (r = 0.99) with a slope of 19.5 ± 0.5 mV per decade of concentration,...

متن کامل

Construction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method

In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of colloid and interface science

دوره 265 1  شماره 

صفحات  -

تاریخ انتشار 2003