Myocardial perforation by flexible Elema endocardial pacing catheters.

نویسندگان

  • B J Hurwitz
  • M M Zion
  • I W Obel
چکیده

Hurwitz, B. J., Zion, M. M., and Promund Obel, I. W. (1974). Thorax, 29, 678-684. Myocardial perforation by flexible Elema endocardial pacing catheters. Myocardial perforation as a complication of permanent endocardial pacing with flexible Elema catheters is described in nine patients. In eight patients pacing failed, but there were no other serious ill-effects. Diaphragmatic pacing occurred in five patients. Radiological evidence of movement, either posteriorly and/or laterally, of the electrode tip was detected in five patients. In only two of them was the electrode seen to be definitely extracardiac in position. A change in the pacing wave form aided the diagnosis in two patients. In a further two patients electrode tip electrocardiograms helped to confirm the diagnosis where, upon withdrawal of the perforating electrode, small Q waves disappeared, RS complexes enlarged, and the ST segments became more elevated, with deeply inverted T waves. Withdrawal and repositioning of the electrode catheters was performed in seven patients. In one, a new catheter was inserted, and in another, where uninterrupted cardiac pacing was accompanied by intermittent diaphragmatic pacing, the pacing system was left unaltered. The follow-up is from six months to four and a half years with one late death apparently unrelated to pacing failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term epicardial ventricular pacing from endocardial bipolar pacemaker lead: perforation of right atrial wall.

One of the hazards of endocardial cardiac pacing is that the pacemaker lead may perforate the myocardial wall or interventricular septum although the incidence of such perforations is believed to be small. This paper describes what is believed to be a unique case in which a pacemaker lead perforated the atrial wall at implantation (or possibly shortly afterwards) and yet gave satisfactory right...

متن کامل

Robotic positioning of standard electrophysiology catheters: a novel approach to catheter robotics.

BACKGROUND Robotic systems have been developed to manipulate and position electrophysiology (EP) catheters remotely. One limitation of existing systems is their requirement for specialized catheters or sheaths. We evaluated a system (Catheter Robotics Remote Catheter Manipulation System [RCMS], Catheter Robotics, Inc., Budd Lake, New Jersey) that manipulates conventional EP catheters placed thr...

متن کامل

Long-term follow up of cardiac pacing threshold using a noninvasive method of measurement.

Seventeen patients were followed up for a period ranging from 12 to 40 months after implantation of an Elema Vario pacemaker with an endocardial electrode. Two patients had a greater stimulation threshold beyond 6 months after implantation than the maximum threshold recorded before 6 months. One of these patients required replacement of the pacing system because of exit block. The 16 patients w...

متن کامل

Intracardiac pacing as emergency treatment in Adams-Stokes syndrome.

In most cases of atrioventricular block with Adams-Stokes attacks the application of either an endocardial or an epicardial electrode for artificial pacing can be performed in the operating-theatre with all necessary equipment available. In some cases, however, the situation is more dramatic: electrical pacing may be necessary without any delay, and it may be impossible to transfer the patient ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 1974