Temperature Control of Industrial Water Cooler using Hot-gas Bypass
ثبت نشده
چکیده
Abstract—In this study, we experiment on precise control outlet temperature of water from the water cooler with hot-gas bypass method based on PI control logic for machine tool. Recently, technical trend for machine tools is focused on enhancement of speed and accuracy. High speedy processing causes thermal and structural deformation of objects from the machine tools. Water cooler has to be applied to machine tools to reduce the thermal negative influence with accurate temperature controlling system. The goal of this study is to minimize temperature error in steady state. In addition, control period of an electronic expansion valve were considered to increment of lifetime of the machine tools and quality of product with a water cooler.
منابع مشابه
Testing of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)
This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...
متن کاملExperimental Study of a CO2 Thermal Battery for Simultaneous Cooling and Heating Applications
This paper presents experimental investigations of the dynamics of a transcritical CO2 heat pump system with two thermal storages for simultaneous cooling and heating application. The preliminary results of the thermal battery are provided using a small-scale test bed that shows the accelerated penetration of renewable energy sources for building heating and cooling applications. The experiment...
متن کاملField Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control
Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...
متن کاملInvestigating the microbial quality of cooler drinking water of hospitals, clinics and health centres of Behbahan in 2014
Background and aims: The main cause of many problems in developing countries is related to the provision of safe drinking water. Since the health of drinking water is important in the busy centers such as hospitals, clinics and health centers, this study was done to investigate the role of water coolers connected to the municipal system in microbial quality of drinking water in...
متن کاملOptimization and increase production and efficiency of gas turbines GE-F9 using Media evaporative cooler in Fars combined cycle power plant
Gas turbines play an important role in supplying power for the country especially in peak electricity load. The main disadvantages are the turbines, they produce large changes are a result of climate change. However, in times of peak electricity grid and at the same time warm months, can produce gas turbines under the effect of ambient temperature, the amount of reduced considerably. The method...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009