Comparative Analysis of Urinary Total Proteins by Bicinchoninic Acid and Pyrogallol Red Molybdate Methods.

نویسندگان

  • Padma Yalamati
  • Aparna Varma Bhongir
  • Madhulatha Karra
  • Sashidhar Rao Beedu
چکیده

BACKGROUND The concentration of total proteins in urine is a good index of renal function, but its determination is found to be unreliable. The pyrogallol red molybdate (PRM) method for urine total proteins is being widely used in most of the hospitals because of its high sensitivity, better precision and its practicability. Bicinchoninic acid method (BCA) is also used for protein estimation and there have been no studies comparing this method with the PRM method in human urine samples. BCA method overestimates the urinary protein concentration in the presence of interfering substances. After removing the interfering substances present in the human urine samples the results of BCA method were compared with the PRM method. AIM The purpose of the study is to identify whether the results of urine total proteins by BCA method are comparable to PRM method and can be used as an alternative to the PRM method. SETTING AND DESIGN This is a cross-sectional study done on fresh urine specimens from the hospital laboratory, covering a wide range of protein concentrations. MATERIAL AND METHODS Fresh urine specimens covering a wide range of protein concentrations (urine dipstick: nil, trace, 1+, 2+ and ≥ 3+) of 36 patients were analysed by both the methods. STATISTICAL ANALYSIS Imprecision was determined by repeated analysis study and Inaccuracy was assessed by comparing the results of the patient's urine samples by both the methods using correlation plots, Bland and Altman, and Passing and Bablok regression analyses. RESULTS The coefficient of variation and mean (SD) for the BCA method were 4.6% and 799.1 (882.5) mg/L and for the PRM method were 5.1% and 802.1 (911.9) mg/L. The Pearson correlation coefficient, r was 0.93 (p < 0.0001). Method agreement studies showed no significant constant and proportional bias between both the methods. CONCLUSION In urine which is subjected to removal of interfering substances, the BCA results are comparable to PRM method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An improved pyrogallol red-molybdate method for determining total urinary protein.

We adapted the pyrogallol red-molybdate method for total urinary protein to the Cobas Bio centrifugal analyzer. The method is simple, rapid, sensitive, and inexpensive. Addition of 25 mg of sodium dodecyl sulfate per liter to the reagent modifies protein reactivities so that the chromogenicity of human gamma globulins is the same as that of albumin. Results by this method and a comparison metho...

متن کامل

Total protein determination in urine: elimination of a differential response between the coomassie blue and pyrogallol red protein dye-binding assays.

BACKGROUND The total protein content of urine is a good index of renal function, but its determination is unreliable. Protein dye-binding assays are simple, but they characteristically lack a uniform response to different proteins. METHODS We investigated a differential response of the Sigma Microprotein Coomassie Brilliant Blue (CBB) and Pyrogallol Red-molybdate (PRM) protein dye-binding ass...

متن کامل

Rapid detection of cystic fibrosis transmembrane conductance regulator gene IVS8 5T variant by real-time PCR.

with specific marker proteins in routine laboratories , in which nephelometric instrumentation is frequently available but manpower is limited and the expert knowledge required to interpret proteinuria is lacking. improved pyrogallol red-molybdate method for determining total urinary protein. Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 auto...

متن کامل

Urine Total Protein Measurement with the Vitros Dry Reagent Technology: Modification of Diluent to Re- solve Positive Bias of Diluted Samples, Patrick Lionel

The measurement of urinary total protein continues to have a place in the repertoire of clinical laboratory tests, particularly in the clinical assessment of patients with renal disease. Although the test volume is often modest, there exists the need to perform the assay on the major automated chemistry analyzers currently in use in most hospital laboratories. We have evaluated the performance ...

متن کامل

Influence of a variable differential function on the stone-growth-related urinary depletion effect.

sodium oxalate without SDS) by varying the concentration of the dye (0.03 or 0.12 mmol/L), sodium oxalate (0 or 2 mmol/L), and SDS (25 or 100 mg/L) in all combinations. For protein assays, we mixed 20 ␮L of sample, calibrator, or water (blank) with 1 mL of PRM reagent and measured the absorbance at 600 nm after 30 min against the blank. The effects of the aminoglycosides on the absorbance readi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical and diagnostic research : JCDR

دوره 9 8  شماره 

صفحات  -

تاریخ انتشار 2015