Optical coherence tomography for the monitoring of neovascular age-related macular degeneration: a systematic review.

نویسندگان

  • Mayret M Castillo
  • Graham Mowatt
  • Andrew Elders
  • Noemi Lois
  • Cynthia Fraser
  • Rodolfo Hernández
  • Winfried Amoaku
  • Jennifer M Burr
  • Andrew Lotery
  • Craig R Ramsay
  • Augusto Azuara-Blanco
چکیده

TOPIC To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition. CLINICAL RELEVANCE Traditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests. METHODS Systematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias. RESULTS We included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%-93%) and 48% (95% CI, 30%-67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias. CONCLUSIONS There is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography, fluorescein angiography, and the management of neovascular age-related macular degeneration.

In the article by Castillo et al (http://www.aaojournal.org/ article/S0161-6420(14)00728-3/fulltext), the authors provide a thoughtful review of “the accuracy of optical coherence tomography (OCT) [compared] with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.” The topic is impo...

متن کامل

Implications of the anatomical classification of the neovascular form of age-related macular degeneration.

OBJECTIVE To present the clinical relevance of the anatomical classification of the neovascular form of Age-Related Macular Degeneration (AMD). METHODS Critical analysis of the current situation in the management of patients with neovascular AMD, by reviewing the available scientific evidence with regards to the classification of the types of neovascular lesion by angiography and optical cohe...

متن کامل

Effect of intravitreous anti-vascular endothelial growth factor therapy on choroidal thickness in neovascular age-related macular degeneration using spectral-domain optical coherence tomography.

A critical method of monitoring patients with neovascular age-related macular degeneration (AMD) being treated with anti–vascular endothelial growth factor (anti-VEGF) is optical coherence tomography (OCT), which uses low-coherence interferometry of light to examine the retina in vivo on a micrometer scale. Recent advances in spectral-domain OCT make visualization of the choroid feasible. Using...

متن کامل

Spectral domain optical coherence tomography for quantitative evaluation of drusen and associated structural changes in non-neovascular age-related macular degeneration

BACKGROUND/AIMS To demonstrate how spectral domain optical coherence tomography (SDOCT) can better evaluate drusen and associated anatomical changes in eyes with non-neovascular age-related macular degeneration (AMD) compared with time domain optical coherence tomography (TDOCT). METHODS Images were obtained from three eyes of three patients with AMD using an experimental SDOCT system. Both a...

متن کامل

Anti-VEGF-refractory Exudative Age-related Macular Degeneration: Differential Response According to Features on Optical Coherence Tomography

PURPOSE To describe optical coherence tomography (OCT) characteristics of neovascular age-related macular degeneration (AMD) patients refractory to intravitreal anti-vascular endothelial growth factor (VEGF) injections (ranibizumab, bevacizumab) and their responses to alternative anti-VEGF agents or photodynamic therapy (PDT). METHODS A retrospective review of 267 neovascular AMD patients tre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ophthalmology

دوره 122 2  شماره 

صفحات  -

تاریخ انتشار 2015