Comparison � of Different Figure of Merit Functions for Dynamic Single Photon Emission Computed Tomography ( dSPECT )

نویسندگان

  • Christophe Blondel
  • Dominikus Noll
  • Jean Maeght
  • Anna Celler
  • Troy Farncombe
چکیده

Dynamic Single Photon Emission Computed Tomography (dSPECT) is a technique which visualizes changing activity distributions in the human body, using dynamic emission data acquired during a single rotation of a standard SPECT camera system. The reconstruction process in dSPECT is based on nonlinear regularization and optimization techniques, and we presently compare a number of possible problem oriented figures of merit based on different spatial and temporal regularization techniques. The accuracy of dSPECT in terms of temporal and spatial resolution is tested in a simulated dynamic cardiac study and a dynamic renal patient study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures

Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...

متن کامل

Performance of the dynamic single photon emission computed tomography (dSPECT) method for decreasing or increasing activity changes.

Radionuclide imaging is now widely used whenever functional information is required. We present a new approach to dynamic SPECT imaging (dSPECT method) that uses a single slow rotation of a conventional camera and allows us to reconstruct a series of 3D images corresponding to the radiotracer distribution in the body at various times. Using simulations of various camera configurations and acqui...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Investigation of the dynamic SPECT (dSPECT) method for Teboroxime using a 4-D kinetic thorax model dMCAT

Tomographic SPECT allows us to visualize, in 3D, the distribution of radiopharmaceuticals in the body which are reconstructed from a series of two dimensional measurements performed around the investigated object. The dSPECT method extends these capabilities into the fourth dimension and creates a series of dynamic 3D images which can be obtained from a single set of dynamic data acquired using...

متن کامل

Brain Single Photon Emission Computed Tomography Scan (SPECT) and Functional MRI in Systemic Lupus Erythematosus Patients with Cognitive Dysfunction: A Systematic Review

Objective(s): Systemic lupus erythematosus (SLE) is an autoimmune disease with a wide range of clinical manifestations. Cognitive dysfunction is one of the manifestations that could present prior to the emergence of any other neuropsychiatric involvements in SLE. Cognitive dysfunction is a subtle condition occurring with ahigh frequency. However, there is no data on the correlation of cognitive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -