The Mitral Valve Orifice Method for Noninvasive Two - dimensional Echo Doppler Determinations of Cardiac Output DANIEL

نویسنده

  • DANIEL C. FISHER
چکیده

We developed and validated a mitral valve orifice method for Doppler cardiac output determination. In 15 open-chest dogs, cardiac output was controlled and measured by a roller pump interposed between the right atrium and pulmonary artery as a right-heart bypass. Left heart flows were measured in the open-chest dog model by Doppler measurements at the mitral valve orifice and compared not only to volume flow measured by the roller pump, but to electromagnetic flow meters as well. The maximum mitral valve orifice area was measured off short-axis two-dimensional echocardiographic views by planimetry. The maximal orifice was then adjusted for its diastolic variation in size by calculating a ratio of mean-to-maximal mitral valve separation on a derived M-mode echocardiogram. Flow was sampled parallel to mitral valve inflow in a four-chamber plane. The multiplication of mean flow throughout the cardiac cycle by the mean mitral valve area after correction for diastolic size variation yielded a cardiac output determination that could be compared to the roller pump measurement. Fifty-two cardiac output determinations over roller pump values of 1-5 1/min yielded a high correlation between roller pump flows and Doppler (r = 0.97 + 0.23 1/min). Our study shows that the mitral valve orifice provides an accurate site for Doppler cardiac output measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The mitral valve orifice method for noninvasive two-dimensional echo Doppler determinations of cardiac output.

We developed and validated a mitral valve orifice method for Doppler cardiac output determination. In 15 open-chest dogs, cardiac output was controlled and measured by a roller pump interposed between the right atrium and pulmonary artery as a right-heart bypass. Left heart flows were measured in the open-chest dog model by Doppler measurements at the mitral valve orifice and compared not only ...

متن کامل

دریچه میترال دو دهانه با تنگی شدید، یک مورد نادر

Double orifice mitral valve (DOMV) is an uncommon anomaly that was first described by Greenfield. Since then more than 200 cases have been reported. In this anomaly, mitral valve has a single fibrous annulus which opens with two openings into the left ventricle. We report a case of DOMV accompanied with severe stenosis in a 22-year old female who had complaints of moderate dyspnea. In transth...

متن کامل

DIAGNOSTIC METHODS VALVULAR HEART DISEASE Comparative accuracy of two-dimensional echocardiography and Doppler pressure half-time methods in assessing severity of mitral stenosis in patients with and without prior commissurotomy

This study was undertaken to compare the accuracies of the two-dimensional echocardiographic (2DE) and Doppler pressure half-time methods for the noninvasive estimation of cardiac catheterization measurements of mitral valve area in patients with pure mitral stenosis both with and without a previous commissurotomy. Data were retrospectively obtained from 74 consecutive patients who underwent ca...

متن کامل

patients with and without prior commissurotomy

This study was undertaken to compare the accuracies of the two-dimensional echocardiographic (2DE) and Doppler pressure half-time methods for the noninvasive estimation of cardiac catheterization measurements of mitral valve area in patients with pure mitral stenosis both with and without a previous commissurotomy. Data were retrospectively obtained from 74 consecutive patients who underwent ca...

متن کامل

Analysis of interobserver and intraobserver variation of interpretation of the echocardiographic and Doppler flow determination of cardiac output by the mitral orifice method.

The variability of the interpretation by two individuals of a combined echocardiographic and Doppler method of calculating output was studied in 30 normal adults. In each subject three separate cardiac cycles were recorded to calculate maximal mitral valve orifice, the ratio of mean to maximal mitral valve leaflet separation, and the mean flow velocity through the mitral valve. The recordings w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005