An underwater blood pressure measuring device.

نویسندگان

  • Arne Sieber
  • Benjamin Kuch
  • Antonio L'abbate
  • Matthias Wagner
  • Paolo Dario
  • Remo Bedini
چکیده

Measurement of arterial blood pressure is an important vital sign for monitoring the circulation. However, up to now no instrument has been available that enables the measurement of blood pressure underwater. The present paper details a novel, oscillometric, automatic digital blood pressure (BP) measurement device especially designed for this purpose. It consists mainly of analogue and digital electronics in a lexan housing that is rated to a depth of up to 200 metres' sea water, a cuff and a solenoid for inflation of the cuff with air supplied from a scuba tank. An integrated differential pressure sensor, exposed to the same ambient pressure as the cuff, allows accurate BP measurement. Calculation of systolic and diastolic pressures is based on the analysis of pressure oscillations recorded during the deflation. In hyperbaric chamber tests to pressures up to 405 kPa, BP measurements taken with the prototype were comparable to those obtained with established manual and automated methods. Swimming pool tests confirmed the correct functioning of the system underwater. The quality of the recorded pressure oscillations was very good even at 10 metres' fresh water, and allowed determination of diastolic and systolic pressure values. Based on these results we envisage that this device will lead to a better understanding of human cardiovascular physiology in underwater and hyperbaric environments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش یک مورد: ارسال فشار خون و نبض بیمار به پزشک با استفاده از سیستم Global system for Mobile Communications

 Background: Hypertension is a common chronic disease with increasing prevalence worldwide. Regular close monitoring of blood pressure is key point of hypertension management. Home monitoring of blood pressure has its own problems such as lack of early access to a physician in case of emergency. In this study we have designed a device that could send the patient’s self-measured blood pre...

متن کامل

Measuring the spatial distribution of sound pressure in a fish tank under laboratory conditions (Research Article)

Sound-related behavioural studies explore the effects of sound on underwater animals in tanks under controlled laboratory conditions. In this study, we aim to assess sound pressure distributions and gradients in a small-sized water-filled tank that can be used in behavioural studies to examine anthropogenic sound effects on fish and invertebrates and to raise awareness among scientists in the f...

متن کامل

Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement

Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...

متن کامل

EXPERIMENTAL EVALUATION OF BLAST WAVE PARAMETERS IN UNDERWATER EXPLOSION OF HEXOGEN CHARGES

Behavior of blast wave in underwater explosion is of interest to metal forming community and ship designers. Underwater detonation is, also a potential hazard to the water intakes or a plant spent fuel pool. In this paper, some techniques for calculating free-field blast parameters such as pressure and impulse in underwater explosion and prediction of bubble pulsation parameters are presented a...

متن کامل

مقایسه اندازه گیری فشارخون توسط گوشی معمولی با گوشی تلفیقی

Background and Purpose: Blood pressure (BP) is routinely evaluated intermittently during the clinical status for care and treatment. The most common method to measure BP is by using the sphygmomanometer with a stethoscope. This method may be difficult for medical students that will use BP for medical evaluation. The purpose of this study was to compare the accuracy of double stethoscope devic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diving and hyperbaric medicine

دوره 38 3  شماره 

صفحات  -

تاریخ انتشار 2008