Improved computed radiography image quality from a BaFl:Eu photostimulable phosphor plate.

نویسندگان

  • Yasushi Nakano
  • Tomonori Gido
  • Satoshi Honda
  • Akihiro Maezawa
  • Hideaki Wakamatsu
  • Takafumi Yanagita
چکیده

Recent advances in the design of photostimulable phosphor (PSP) plates for computed radiography (CR) systems have made it possible to manufacture plates made of BaFI:Eu phosphor material in the cassette form. The image quality of this plate, six BaF(Br,I):Eu plates, and one BaFBr:Eu plate were evaluated in terms of presampling modulation transfer function (MTF), normalized Wiener spectra (WSN), and detective quantum efficiency (DQE). Compared with the best-performing BaF(Br,I):Eu plate, the BaFI:Eu plate provided DQE that was higher, at spatial frequencies of 0.5, 1.0, and 2.0 cycles/mm, by 12% (21.8 versus 19.4), 13% (18.8 versus 16.7), and 11% (12.0 versus 10.8), respectively. Since presampling MTF values of the two plates were comparable, the BaFI:Eu plate's higher DQE is attributable to total WSN conversely being lower by 17% [8.65 x 10(-5) (mm2) versus 10.38 x 10(-5) (mm2)], 17% [5.85 x 10(-5) (mm2) versus 7.03 x 10(-5) (mm2)], and 12% [2.82 x 10(-5) (mm2) versus 3.19 x 10(-5) (mm2)] at the specified frequencies, respectively, primarily due to the contribution of x-ray quantum WSN. This jibes with the high x-ray absorption provided by the 27%-higher x-ray attenuation coefficients (7.54 versus 6.07, at 60 KeV) that BaFI offers over BaF(Br(0.85),I(0.15)), a result of the high atomic number of BaFI's exclusively iodine halide content. The results were consistent with earlier studies of several of these same plates and indicate that BaFI:Eu is a promising avenue to lower image noise and higher overall CR system image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

A comparative study of image quality and radiation exposure for dental radiographs produced using a charge-coupled device and a phosphor plate system.

AIM To investigate the quality of periapical radiographic images produced by two digital dental radiography systems, a charge-coupled device (CCD) and a photostimulable phosphor (PSP) image plate system, and to examine the overall radiation exposure when using these systems in a clinical setting. METHODOLOGY Patients were randomly allocated to both systems and the resultant radiographs rated ...

متن کامل

Practical guidelines for radiographers to improve computed radiography image quality

Computed Radiography (CR) has become a major digital imaging modality in a modern radiological department. CR system changes workflow from the conventional way of using film/screen by employing photostimulable phosphor plate technology. This results in the changing perspectives of technical, artefacts and quality control issues in radiology departments. Guidelines for better image quality in di...

متن کامل

Comparison of Different Imaging Techniques for the Evaluation of Proximity between Molars and the Mandibular Canal

Background and Aim: To compare the radiographic distance from the inferior part of mandibular second and third molars to the superior border of mandibular canal on radiographs obtained by conventional periapical radiographs, intraoral photostimulable phosphor plate (Intraoral PSP) and panoramic photostimulable phosphor plate (Panoramic PSP). Subjects and Methods: The study was carried out on 25...

متن کامل

Evaluation of the Performance of Computed Radiography Systems with Different Sources and Different Configurations

Computed radiography (CR) is a digital radiographic technique, which uses very similar equipment to conventional radiography except that in place of a film to create the latent image, an imaging plate (IP) made of a photostimulable phosphor is used [1]. CR systems are commonly used in medical applications since they have proven reliability over more than two decades. Conversely, the NDT communi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2002