A bio-optical algorithm for the remote estimation of the chlorophyll-a concentration in case 2 waters

نویسندگان

  • Anatoly A Gitelson
  • Daniela Gurlin
  • Wesley J Moses
  • Tadd Barrow
چکیده

The objective of this work was to test the performance of a recently developed three-band model and its special case, a two-band model, for the remote estimation of the chlorophyll-a (chl-a) concentration in turbid productive case 2 waters. We specifically focused on (a) determining the ability of the models to estimate chl-a < 20 mg m−3, typical for coastal and estuarine waters, and (b) assessing the potential of MODIS and MERIS to estimate chl-a concentrations in turbid productive waters, using red and near-infrared (NIR) bands. Reflectance spectra and water samples were collected in 89 stations over lakes in the United States with a wide variability in optical parameters (i.e. 2.1 < chl-a < 184 mg m−3; 0.5 < Secchi disk depth < 4.2 m; 1.2 < total suspended matter < 15 mg l−1). The three-band model, using wavebands around 670, 710 and 750 nm, explains more than 89% of the chl-a variation for chl-a ranging from 2 to 20 mg m−3 and can be used to estimate chlorophyll-a concentrations with a root mean square error (RMSE) of <1.65 mg m−3. MODIS (bands 13 and 15) and MERIS (bands 7, 9, and 10) red and NIR reflectances were simulated from the collected reflectance spectra and potential estimation errors were assessed. The MODIS two-band model is able to estimate chl-a concentrations with a RMSE of <7.5 mg m−3 for chl-a ranging from 2 to 50 mg m−3; however, the model loses its sensitivity for chl-a < 20 mg m−3. Benefiting from the higher spectral resolution of the MERIS data, the MERIS three-band model accounts for 93% of chl-a variation and is able to estimate chl-a concentrations with a RMSE of <5.1 mg m−3 for chl-a ranging from 2 to 50 mg m−3, and a RMSE of <1.7 mg m−3 for chl-a ranging from 2 to 20 mg m−3. These findings imply that, provided that an atmospheric correction scheme specific to the red and NIR spectral region is available, the extensive database of MODIS and MERIS images could be used to quantitatively monitor chl-a in case 2 waters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing the potential of SeaWiFS and MODIS for estimating chlorophyll concentration in turbid productive waters using red and near-infrared bands

Bio-optical algorithms for remote estimation of chlorophyll-a concentration (Chl) in case-1 waters exploit the upwelling radiation in the blue and green spectral regions. In turbid productive waters other constituents, that vary independently of Chl, absorb and scatter light in these spectral regions. As a consequence, the accurate estimation of Chl in turbid productive waters has so far not be...

متن کامل

Effect of bio-optical parameter variability and uncertainties in reflectance measurements on the remote estimation of chlorophyll-a concentration in turbid productive waters: modeling results.

Most algorithms for retrieving chlorophyll-a concentration (Chla) from reflectance spectra assume that bio-optical parameters such as the phytoplankton specific absorption coefficient (aPhi*) or the chlorophyll-a fluorescence quantum yield (eta) are constant. Yet there exist experimental data showing large ranges of variability for these quantities. The main objective of this study was to analy...

متن کامل

Effect of bio-optical parameter variability on the remote estimation of chlorophyll-a concentration in turbid productive waters: experimental results.

The analytical development and underlying hypothesis of a three-band algorithm for estimating chlorophyll-a concentration ([Chla]) in turbid productive waters are presented. The sensitivity of the algorithm to the spectral location of the bands used is analyzed. A large set of experimental observations ([Chla] varied between 4 and 217 mg m(-3) and turbidity between 2 and 78 nephelometric turbid...

متن کامل

Normalized difference chlorophyll index: A novel model for remote estimation of chlorophyll-a concentration in turbid productive waters

a r t i c l e i n f o Keywords: Chlorophyll-a Normalized difference chlorophyll index Remote sensing reflectance Spectral algorithm Turbid productive waters MEdium Resolution Imaging Spectrometer We propose a normalized difference chlorophyll index (NDCI) to predict chlorophyll-a (chl-a) concentration from remote sensing data in estuarine and coastal turbid productive (case 2) waters. NDCI cali...

متن کامل

The OLCI Neural Network Swarm (ONNS): A Bio-Geo-Optical Algorithm for Open Ocean and Coastal Waters

The processing scheme of a novel in-water algorithm for the retrieval of ocean color products from Sentinel-3 OLCI is introduced. The algorithm consists of several blended neural networks that are specialized for 13 different optical water classes. These comprise clearest natural waters but also waters reaching the frontiers of marine optical remote sensing, namely extreme absorbing, or scatter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009