Dynamic state - space estimation of the hemodynamic response with Near - Infrared Spectroscopy
نویسنده
چکیده
Near-Infrared Spectroscopy (NIRS) allows the recovery of the hemodynamic response associated with evoked brain activity. The signal is contaminated with systemic physiological interference which occurs in the superficial layers of the head as well as in the brain tissue. The back-reflection geometry of the measurement makes the DOI signal strongly contaminated by systemic interference occurring in the superficial layers. A recent development has been the use of signals from small source-detector separation (1 cm) optodes as regressors. Since those additional measurements are mainly sensitive to superficial layers in adult humans, they help in removing the systemic interference present in longer separation measurements (3 cm). Encouraged by those findings, we developed a dynamic estimation procedure to remove global interference using small optode separations and to estimate simultaneously the hemodynamic response. The algorithm was tested by recovering a simulated synthetic hemodynamic response added over baseline DOI data acquired from 6 human subjects at rest. The performance of the algorithm was quantified by the Pearson R2 coefficient and the mean square error (MSE) between the recovered and the simulated hemodynamic responses. Our dynamic estimator was also compared with a static estimator and the traditional adaptive filtering method. We observed a significant improvement (two-tailed paired t-test, p < 0.05) in both HbO and HbR recovery using our Kalman filter dynamic estimator compared to the traditional adaptive filter, the static estimator and the standard GLM technique. We then show that the systemic interference occurring in the superficial layers of the human head is inhomogeneous across the surface of the scalp. As a result, the improvement obtained by using a short separation optode decreases as the relative distance between the short and the long measurement is increased. NIRS data was acquired on 6 human subjects both at rest and during a motor task consisting of finger tapping. The effect of distance between the short and the long channel was first quantified by recovering a synthetic hemodynamic response added over the resting-state data. The effect was also observed in the functional data collected during the finger tapping task. Together, these results suggest that the short separation measurement must be located as close as 1.5 cm from the standard NIRS channel in order to provide an improvement which is of practical use. In this case, the improvement in Contrast-to-Noise Ratio (CNR) compared to a standard GLM procedure without using any small separation optode reached 50% for HbO and 100% for HbR. Using small separations located farther than 2 cm away resulted in mild or negligible improvements only. Thesis Supervisor: David A. Boas Title: Associate Professor of Radiology
منابع مشابه
Optical Imaging of the Motor Cortex in the Brain in Order to Determine the Direction of the Hand Movements Using Functional Near-Infrared Spectroscopy (fNIRS)
Introduction: In recent years, optical imaging has attracted a lot of attention from scholars as a non- aggressive, efficient method for evaluating the activities of the motor cortex in the brain. Functional near-infrared spectroscopy (fNIRS (is a tool showing the hemodynamic changes in a cortical area of the brain according to optical principles. The present study has been de...
متن کاملNondestructive Firmness Estimation of Tomato Fruit Using Near-Infrared Spectroscopy
Today, nondestructive methods are widely used to determine the quality of agricultural products. Meanwhile, visible and near-infrared (Vis/NIR) spectroscopy is regarded as one of the most widely used methods in the field of quality assessment of agricultural products. In this study, a system was developed to measure the Vis/NIR spectra of tomato fruit samples in the half-transmittance mode of m...
متن کاملDevelopment of near infrared reflectance spectroscopy (NIRS) calibration model for estimation of oil content in a worldwide safflower germplasm collection
The development of NIRS calibration model as a rapid, precise, robust, and cost-effective method to estimate oil content in ground seeds of worldwide safflower germplasm collection grown under different agro-climatic conditions was the key objective of this research project. The oil content was measured by accelerated solvent extraction method in a total of 328 samples collected across 2004 (16...
متن کاملComputational Method for Representing the Simultaneous Hemodynamic Relationship between Oxy-Hemoglobin Delivery and Deoxy-Hemoglobin Extraction in Neural Tissues
In this study, we propose the use of phase space plot analysis to characterize coupling relationships between two simultaneously recorded hemodynamic variables, i.e., oxyhemoglobin (oxy-Hb) and deoxy-hemoglobin (deoxy-Hb), using functional near-infrared spectroscopy (fNIRS). To demonstrate the validity of the proposed method, we analyze hemodynamic data recorded from human subjects performing a...
متن کاملA GLM-Based Approach to Estimate Stimulus- Evoked Hemodynamic Response from fNIRS Measurements
Functional near-infrared spectroscopy (fNIRS) uses near-infrared light to measure changes in the concentration of oxygenated (HbO) and deoxygenated hemoglobin (HbR). Physiological processes, such as heart beat, respiration, vasomotor waves, induce concentration changes of HbO and HbR well detectable in the fNIRS signal. Some of these physiological components, as well as random disturbances, can...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011