Transcatheter closure of atrial septal defects--is balloon sizing still necessary?

نویسندگان

  • Swee Chye Quek
  • Wen X Wu
  • Kit Y Chan
  • Ting F Ho
  • William C Yip
چکیده

INTRODUCTION The device closure of atrial septal defects has evolved over the years. In the early days of transcatheter occlusion, balloon sizing was used to choose an appropriate sized device. We postulate that balloon sizing does not value-add to the procedure and is unnecessary. MATERIALS AND METHODS Patients who had balloon sizing, with (Group 1, n = 38) or without (Group 2, n = 21) atrial septal defect closure, were compared to another group (Group 3, n = 64) who had atrial septal defect closure without balloon sizing. Although the atrial septal defect size (mm) in those without balloon sizing (Group 3) compared to patients who had balloon sizing (Group 1) (18.3 +/- 5.4 vs 14.8 +/- 5.8; P = 0.021) was larger, the Amplatzer septal occluder size chosen (mm) (21.6 +/- 6.3 vs 21.2 +/- 8.1; P = 0.693) was similar. RESULTS We analysed the degree of absolute sizing, defined as [(Balloon or Amplatzer occluder size) - (transoesophageal echocardiography size)], versus relative sizing, which is defined as [(Balloon or Amplatzer occluder size)--(transoesophageal echocardiography size) / (Balloon or Amplatzer occluder size)]. It was evident that there was greater absolute and relative over-sizing (6.3 +/- 4.4 mm vs 4.2 +/- 2.1 mm; P = 0.009 and 28.3 +/- 15.4% vs 20.0 +/- 7.0%; P = 0.001, respectively) in patients with balloon sizing (Group 1) compared to those who did not (Group 3). Even a greater degree of absolute (5.1 +/- 3.9 mm vs 9.5 +/- 4.7 mm; P <0.001) and relative over-sizing (24.8 +/- 15.6% vs 33.0 +/- 13.6%; P = 0.001) was observed in patients who had balloon sizing but there was no closure (Group 2) compared to those who had balloon sizing and closure of their defects (Group 1). CONCLUSION Our results showed that balloon sizing tended to over-size the atrial septal defect. This may have an important bearing in selecting a larger device than necessary, or even precluding transcatheter closure of the larger atrial septal defects. It is also associated with increased procedural, fluoroscopy time and cost. We suggest that balloon sizing may no longer be necessary in the protocol of device closure of an atrial septal defect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Echocardiographic visualization of laceration of atrial septum during balloon sizing of atrial septal defect.

Transcatheter closure of atrial septal defect (ASD) has become an accepted alternative to surgery. A number of complications associated with ASD device closure have been recognized but most are rare or minor in severity. We report a rare complication of atrial septal laceration during transcatheter closure of secundum ASD. We discuss the diagnostic confusion, which resulted in the decision for ...

متن کامل

A comparison between size of the occluder device and two-dimensional transoesophageal echocardiographic sizing of the ostium secundum atrial septal defect

OBJECTIVES Transcatheter closure of a secundum atrial septal defect (ASD II) has become an effective alternative for surgical treatment. In this study we evaluated the correlation between the two-dimensional transoesophageal echocardiographic (2D TEE) sizing of ASDs and the actual diameter of occluders in patients undergoing device closure. METHODS The records of 54 patients who underwent tra...

متن کامل

Transcatheter Closure of Atrial Septal Defects in Children, Middle-Aged Adults, and Older Adults: Failure Rates, Early Complications; and Balloon Sizing Effects

Objectives. To compare the failure ratio and inhospital complications across three age groups of patients and to investigate the effects of balloon sizing on the success and the device diameter. Methods. This retrospective review was of 665 patients who had been listed for transcatheter-based closure of ASD between 1999 and 2010. The patients were divided into three age groups: children (<18 ye...

متن کامل

Sizing of atrial septal defects by intracardiac echocardiography for device closures.

BACKGROUND Transcatheter closure of a secundum atrial septal defect (ASD) has become an effective method for surgical treatment. In this study, we evaluated the feasibility and accuracy of intracardiac echocardiography (ICE) for sizing ASDs compared with conventional methods. METHODS Between January 2004 and December 2006, 270 patients underwent transcatheter closure of secundum ASD by using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of the Academy of Medicine, Singapore

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 2010