Dobutamine stress tagging and gradient-echo imaging for detection of coronary heart disease at 3 T.

نویسندگان

  • D Thomas
  • C Meyer
  • K Strach
  • C P Naehle
  • J Mazraeh
  • T Gampert
  • H H Schild
  • T Sommer
چکیده

OBJECTIVE The purpose of this study was to evaluate the feasibility and diagnostic accuracy of a combined spoiled gradient-echo (sGRE) and tagged gradient-echo (SPAMM-GRE) protocol for detection of coronary artery disease (CAD) during high-dose dobutamine stress at 3 T. METHOD The study protocol was approved by the local ethics committee. For stress testing, a standard high-dose dobutamine protocol was employed. Image quality at the highest stress level and diagnostic accuracy of the sGRE and SPAMM-GRE sequences were compared. The final study population consisted of 37 patients. RESULTS The mean image quality score was 2.6±0.6 for the sGRE sequence and 2.4±0.6 for the SPAMM-GRE sequence (p>0.05). Sensitivity, specificity and diagnostic accuracy were 0.81, 0.86, 0.84 and 0.88, 0.86, 0.86 for the sGRE and SPAMM-GRE, respectively. In three cases with new wall motion abnormalities (WMAs), detected by sGRE and SPAMM-GRE, WMAs were detected at a lower stress level by tagging. CONCLUSION The combined sGRE and SPAMM-GRE high-dose dobutamine protocol at 3 T is feasible and delivers good diagnostic accuracy. Tagging increases the sensitivity of high-dose dobutamine stress testing for detection of CAD and may allow for detection of new WMAs at lower stress levels compared with sGRE alone.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced cardiac MR imaging of ischemic heart disease.

Important advances in rapid magnetic resonance (MR) imaging technology and its application to cardiovascular imaging have been made during the past decade. High-field-strength clinical magnets, high-performance gradient hardware, and ultrafast pulse sequence technology are rapidly making the vision of a comprehensive "one-stop shop" cardiac MR imaging examination a reality. This examination is ...

متن کامل

Noninvasive diagnosis of ischemia-induced wall motion abnormalities with the use of high-dose dobutamine stress MRI: comparison with dobutamine stress echocardiography.

BACKGROUND The analysis of wall motion abnormalities with dobutamine stress echocardiography (DSE) is an established method for the detection of myocardial ischemia. With ultrafast magnetic resonance tomography, identical stress protocols as used for echocardiography can be applied. METHODS AND RESULTS In 208 consecutive patients (147 men, 61 women) with suspected coronary artery disease, DSE...

متن کامل

Magnetic Resonance Imaging During Dobutamine Stress for Detection

Background Quantitative measurement of wall motion is essential to assess objectively the functional significance of coronary artery disease. We developed a quantitative wall thickening analysis on stress magnetic resonance images. This study was designed to assess the clinical value of magnetic resonance imaging (MRI) during dobutamine stress for detection and localization of myocardial ischem...

متن کامل

Comparison of dobutamine stress magnetic resonance, adenosine stress magnetic resonance, and adenosine stress magnetic resonance perfusion.

BACKGROUND Dobutamine stress MR (DSMR) is highly accurate for the detection of inducible wall motion abnormalities (IWMAs). Adenosine has a more favorable safety profile and is well established for the assessment of myocardial perfusion. We evaluated the diagnostic value of IWMAs during dobutamine and adenosine stress MR and adenosine MR perfusion compared with invasive coronary angiography. ...

متن کامل

Magnetic resonance stress tagging in ischemic heart disease.

High-dose dobutamine magnetic resonance stress testing has been shown to be superior to dobutamine stress echocardiography for diagnosis of coronary artery disease (CAD). We determined the feasibility of quantitative myocardial tagging during low- and high-dose dobutamine stress and tested the ability of global systolic and diastolic quantitative parameters to identify patients with significant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of radiology

دوره 84 997  شماره 

صفحات  -