Development of dosimetry using detectors of diagnostic digital radiography systems.

نویسندگان

  • Eiji Ariga
  • Shigeki Ito
  • Shizuhiko Deji
  • Takuya Saze
  • Kunihide Nishizawa
چکیده

Dosimetry using an imaging plate (IP) of computed radiography (CR) systems was developed for quality control of output of the x-ray equipment. Sensitivity index, or the S number, of the CR systems was used for estimating exposure dose under the routine condition: exposure dose from 1.0 to 1.0 x 10(2) microC kg(-1), tube voltages from 50 to 120 kV, and added filtration from 0 to 4.0 mm Al. The IP was calibrated by using a 6 cc ionization chamber having traceability to the National Standard Ionization Chamber. The uncertainty concerning the fading effect was suppressed less than 1.9% by reading the latent image 4 min+/-5 s after irradiation at the room temperature 25.9+/-1.0 degrees C. The S number decreased linearly on the logarithmic graph regardless of the beam quality as exposure dose increased. The relationship between the exposure dose (E) and the S number was fitted by the equation E=a' X S(-b). The coefficient a' decreased when the added filtration and the tube voltage were increased. The coefficient b was 0.977+/-0.007 in all beam qualities. The dosimetry using the IP and the equation can estimate the exposure dose in a range from 9.0 x 10(-2) to 5.0 microC kg(-1) within an uncertainty of +/-5% required by the Japanese Industry Standard. This dose range partially included the doses under routine condition. The doses between 1.0 and 1.0 x 10(2) microC kg(-1) under the routine condition can be shifted to the 5% region by using an absorber. The IP dosimetry is applicable to the quality control of the CR systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Image quality and dose management in digital radiography: a new paradigm for optimisation.

The advent of digital imaging in radiology, combined with the explosive growth of technology, has dramatically improved imaging techniques. This has led to the expansion of diagnostic capabilities, both in terms of the number of procedures and their scope. Throughout the world, film/screen radiography systems are being rapidly replaced with digital systems. Many progressive medical institutions...

متن کامل

The Practice of Chest Radiography Using Different Digital Imaging Systems: Dose and Image Quality

Introduction: The study was undertaken to evaluate the practice of chest radiography using different digital imaging systems and its influence on dose and image quality.  Materials and Methods: The study was carried out in two hospitals from March 2016 to June 2016. Sixty ambulatory patients aged 21 to 60 years who were able to cooperate without difficulty and weighed between 60 to 80 kg were ...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

In Vivo Diagnostic Accuracy of Digital Radiography in the Detection of Secondary Caries in Anterior Teeth

Background and Aim: Secondary caries are a common challenge for dentists. Many researchers have evaluated the accuracy of digital radiographic systems in the detection of secondary caries and have reported controversial results. Therefore, the aim of this in vivo study was to determine the diagnostic accuracy of digital radiography in the detection of secondary caries in anterior teeth. Mate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2007