Novel Techniques regarding Specific Absorption Rate and Field of View Reduction in Magnetic Resonance Imaging

نویسندگان

  • Emre Kopanoglu
  • Cengizhan Öztürk
  • Levent Onural
  • Vakur B. Ertürk
چکیده

NOVEL TECHNIQUES REGARDING SPECIFIC ABSORPTION RATE AND FIELD OF VIEW REDUCTION IN MAGNETIC RESONANCE IMAGING Emre Kopanoglu Ph.D. in Electrical and Electronics Engineering Supervisors: Prof. Dr. Ergin Atalar Assoc. Prof. Dr. Vakur B. Ertürk September, 2012 In this dissertation, novel strategies regarding the reduction of the specific absorption rate (SAR) and the reduction of the total scan time, and analytic calculation methods for the lower limit on the specific absorption rate and the upper limit on the signal-to-noise ratio (SNR) are proposed. The first contribution of this dissertation is on the ultimate intrinsic signal-to-noise ratio (UISNR) and the ultimate intrinsic specific absorption rate (UISAR). Analytic expressions that are valid for arbitrarily shaped subjects are derived for these two parameters at the quasi-static limit. By comparing the UISNR expression to a previously published semi-analytic method for a cylindrical subject, it is shown that the maximum error is below 10%. In the primary contribution of this dissertation, gradient fields with nonlinear variation in space are used for radio-frequency (RF) excitation pulse design. When such fields are used for a pulse design, the relation between the excitation profile and the RF pulse is altered, which leads to a different RF envelope and hence, a different SAR value. Using simulations and experiments, SAR reductions between 15% 54% are demonstrated, in three case studies. Another topic of this dissertation is on the reduction of the total scan time using nonlinear gradient fields. It is demonstrated that, when nonlinear gradient fields are used for excitation, the excitation region can be focused along more than a single direction. Furthermore, with a careful selection of readout encoding direction, reduced field-of-view imaging can be made without changing the SAR or the echo time. In a volunteer experiment, 60% reduction in the total scan time is obtained. The last topic of this dissertation is on curved slice imaging. It is shown using simulations that RF encoding can be used for imaging a curved field-of-view with non-rectangular and nonuniform voxels that may conform to iv

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques

The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...

متن کامل

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Correlation between condyle morphology and disk position of disc displacement in patients with TMJ internal derangements by magnetic resonance imaging

Background and Aims :The most frequent cause of TMJ dysfunction is internal derangement which that largely involves  the function of the articular disc. Anterior disc displacement (ADD) is one of the major findings in TMJ internal derangement. Since the importance of knowledge of its etiology and also The role of all structural indicators association with TMD was not evaluated, in this researc...

متن کامل

The modeling of induced current density in eyes from static magnetic fields produce by MR scanner

Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012