Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

نویسندگان

  • Ramón Miguéns-Vila
  • Benjamín Martín-Biedma
  • Purificación Varela-Patiño
  • Manuel Ruíz-Piñón
  • Pablo Castelo-Baz
چکیده

Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-crack generated at the point of maximum canal curvature. Material and Methods 60 human mandibular premolars with curvatures between 30-49° and radii between 2-4 mm were used. The root canals were instrumented using the Protaper Universal® and Protaper NEXT® systems, with the aid of the Proglider® system. The obtained samples were sectioned transversely before subsequent analysis with LED transillumination at 2 mm and 8 mm from the apex and at the point of maximum canal curvature. Defects were scored: 0 for no defects; and 1 for micro-cracks. Results Root defects were not observed in the control group. The ProTaper NEXT system caused fewer defects (16.7%) than the ProTaper Universal system (40%) (P<0.05). The ProTaper Universal system caused significantly more micro-cracks at the point of maximum canal curvature than the ProTaper NEXT system (P<0.05). Conclusions Rotary instrumentation systems often generate root defects, but the ProTaper NEXT system generated fewer dentinal defects than the ProTaper Universal system. A higher prevalence of defects was found at the point of maximum curvature in the ProTaper Universal group. Key words:Curved root, Micro-crack, point of maximum canal curvature, ProTaper NEXT, ProTaper Universal, Vertical root fracture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Dentinal Microcrack Incidence After Root Canal Preparation by BioRaCe and Edge Taper Platinum

Background and Aim: Preparation of root canal with rotary nickel-titanium (NiTi) instruments may potentially create microcracks that can lead to vertical root fracture. This study aimed to compare the incidence of crack formation by BioRaCe and Edge Taper Platinum systems in the mesiobuccal canals of extracted first mandibular molars. Materials and Methods: In this experimental study, 50 first...

متن کامل

In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation

Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...

متن کامل

Micro-computed Tomographic Assessment on the Effect of ProTaper Next and Twisted File Adaptive Systems on Dentinal Cracks.

INTRODUCTION The aim of the present study was to evaluate the frequency of dentinal microcracks observed after root canal preparation with ProTaper Next (PTN; Dentsply Maillefer, Ballaigues, Switzerland) and Twisted File Adaptive (TFA; SybronEndo, Orange, CA) systems through micro-computed tomographic analysis. METHODS Twenty moderately curved mesial roots of mandibular molars presenting a ty...

متن کامل

A micro-computed tomographic evaluation of dentinal microcrack alterations during root canal preparation using single-file Ni-Ti systems

The aim of the present study was to evaluate the length of dentinal microcracks observed prior to and following root canal preparation with different single-file nickel-titanium (Ni-Ti) systems using micro-computed tomography (micro-CT) analysis. A total of 80 mesial roots of mandibular first molars presenting with type II Vertucci canal configurations were scanned at an isotropic resolution of...

متن کامل

Lack of causal relationship between dentinal microcracks and root canal preparation with reciprocation systems.

INTRODUCTION This study aimed to evaluate the frequency of dentinal microcracks observed after root canal preparation with 2 reciprocating and a conventional full-sequence rotary system using micro-computed tomographic analysis. METHODS Thirty mesial roots of mandibular molars presenting a type II Vertucci canal configuration were scanned at an isotropic resolution of 14.16 μm. The sample was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017