Measurement and correction of stimulated echo contamination in T2-based iron quantification.

نویسندگان

  • Christina L Sammet
  • Srirama V Swaminathan
  • Haiying Tang
  • Sujit Sheth
  • Jens H Jensen
  • Alvaro Nunez
  • Kristi Hultman
  • Daniel Kim
  • Ed X Wu
  • Gary M Brittenham
  • Truman R Brown
چکیده

The purpose of this study was to characterize the effects of stimulated echo contamination on MR-based iron measurement derived from quantitative T2 images and develop a method for retrospective correction. Two multiple spin-echo (MSE) pulse sequences were implemented with different amounts of stimulated echo contamination. Agarose-based phantoms were constructed that simulate the relaxation and susceptibility properties of tissue with different concentrations of dispersed (ferritin-like) and aggregated (hemosiderin-like) iron. Additionally, myocardial iron was assessed in nine human subjects with transfusion iron overload. These data were used to determine the influence of stimulated echoes on iron measurements made by an MR-based iron quantification model that can separately measure dispersed and aggregated iron. The study found that stimulated echo contamination caused an underestimation of dispersed (ferritin-like) iron and an overestimation of aggregated (hemosiderin-like) iron when applying this model. The relationship between the measurements made with and without stimulated echo appears to be linear. The findings suggest that while it is important to use MSE sequences with minimal stimulated echo in T2-based iron quantification, it appears that data acquired with sub-optimal sequences can be retrospectively corrected using the methodology described here.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Background Gradient Correction for Water and Fat Quantification in 2D Liver Imaging

Introduction Fatty infiltration of the liver is one of the primary features of nonalcoholic fatty liver disease. Therefore, accurate quantification of the liver fat content is an important factor in detecting hepatic diseases. MRI is an efficient noninvasive tool for assessing liver fat content. A commonly used liver fat quantification technique with MRI is a dual echo imaging (two gradient seq...

متن کامل

Myocardial iron quantification using modified Look-Locker inversion recovery (MOLLI) T1 mapping at 3 Tesla

Background Quantification of myocardial iron overload is critical for the management of patients with hemochromatosis. The effects of excess iron on T1 and T2* relaxation times correlate directly with tissue iron concentration. T2* became the clinical standard at 1.5T as it can be easily obtained in a fast one breath-hold ECG gated multi-echo GRE sequence. At 3T, however, T2* quantification can...

متن کامل

Free-breathing myocardial T2* mapping using GRE-EPI and MOCO for myocardial and hepatic iron overload assessment: a multi-centre study

Background T2* measurement is widely used in the assessment of patients at risk for cardiac and hepatic iron overload (1,2). The conventional breath-hold, ECG-triggered, segmented, multi-echo gradient echo sequence (BH MGRE) used for myocardial T2* quantification (3) is very sensitive to respiratory motion and may not be feasible in patients who are unable to breath-hold. To overcome this limit...

متن کامل

Free-breathing Imaging Techniques for Liver Iron Quantification: Comparison with a Validated Breath-hold Technique in Patients with Iron Overload

Introduction: Hepatic iron content (HIC) measurements utilizing quantitative T2* maps have become an increasingly used alternative to traditional HIC evaluation obtained by liver biopsy. The advantages of T2* based HIC measurements are the non-invasive nature of the precedure and a relatively short measurement time. Recently several studies were presented, that correlated biopsy based HIC measu...

متن کامل

R2* for myocardial iron quantification at 3T CMR using an advanced shimming algorithm

Background Quantification of myocardial iron overload is critical for the management of patients with hemochromatosis. T2* relaxation time or its inverse R2*, are currently the noninvasive gold standard at 1.5T, as they strongly correlate with myocardial iron concentration, and are obtained using a fast single breath-hold ECG-gated multi-echo GRE sequence. However, due to high sensitivity to B0...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 31 5  شماره 

صفحات  -

تاریخ انتشار 2013