Corrosion in Haas expanders with and without use of an antimicrobial agent: an in situ study

نویسندگان

  • Cristhiane Ristum BAGATIN
  • Izabel Yoko ITO
  • Marcela Cristina Damião ANDRUCIOLI
  • Paulo NELSON-FILHO
  • José Tarcísio Lima FERREIRA
چکیده

OBJECTIVES The purpose of this study was to evaluate in situ the occurrence of corrosion in the soldering point areas between the wire, silver brazing and band in Haas expanders. MATERIAL AND METHODS Thirty-four 7-12-year-old patients who needed maxillary expansion with a Haas expander were randomly assigned to two groups of 17 individuals each, according to the oral hygiene protocol adopted during the orthodontic treatment: Group I (control), toothbrushing with a fluoride dentifrice and Group II (experimental), toothbrushing with the same dentifrice plus 0.12% chlorhexidine gluconate (Periogard®) mouthrinses twice a week. The appliances were removed after approximately 4 months. Fragments of the appliances containing a metallic band with a soldered wire were sectioned at random for examination by stereomicroscopy, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). Data were analyzed statistically by Fisher's test at 5% significance level. RESULTS The analysis by optical microscopy revealed areas with color change suggestive of corrosion in the soldering point areas joining the band and the wire in all specimens of both groups, with no statistically significant difference between the groups (p=1). The peaks of chemical elements (Ni, Fe, Cr, O, C and P) revealed by EDS were also similar in both groups. CONCLUSION Color changes and peaks of chemical elements suggestive of corrosion were observed in the soldering point areas between the wire, silver brazing and band in both control and experimental groups, which indicate that the 0.12% chlorhexidine gluconate mouthrinses did not influence the occurrence of corrosion in situ.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اثر دستگاه‌های اکسپاندر سریع Haas و Hyrax بررسی ابعاد حفرات بینی

Background and Aim: In treatment of posterior crossbite awareness of the effects of Haas and Hyrax rapid maxillary expanders (RME) on nasal cavity will help the clinician to select the better appliance. This study was carried out to compare the effects of Haas and Hyrax expanders on the nasal cavity of patients treated for posterior crossbite. Materials and Methods: A clinical trial study was ...

متن کامل

Application of mesoporous silica containing benzotriazole in the epoxy coating applied to plain carbon steel and study of its corrosion behavior

The idea of smart inhibitors is based on the principle that an inhibitor is used where needed. This will reduce the use of inhibitors and protect materials in hostile environments. On the other hand, direct addition of the inhibitor within the coating can be harmful, resulting in the loss of inhibitors ability, deterioration in the coating or both of them. An appropriate method for solving thes...

متن کامل

In situ activation of a Ni catalyst with Mo ion for hydrogen evolution reaction in alkaline solution

In this study Ni catalyst have been activated during hydrogen evolution reaction (HER) by adding Mo ions into the alkaline electrolyte. After dissolving different amounts of ammonium molybdate in the 1M NaOH as electrolyte, Ni catalyst was used as cathode for HER. Afterwards a comparison between hydrogen overpotential measured in Ni catalyst with and without in situ activation has been made; th...

متن کامل

CORROSION RESISTANT SOL–GEL COATING ON 2024-T3 ALUMINUM

The inherent reactivity of the Al–Cu alloys is such that their use for structural, marine, and aerospace components and structures would not be possible without prior application of a corrosion resistance system. Historically these corrosion resistance coatings were based on the use of chemicals containing Cr (VI) compounds. Silane coatings are of increasing interest in industry due to th...

متن کامل

بررسی فعالیت ضدمیکروبی نانوالیاف پلیمری با افزودنی عصارۀ حنا

Main agent orange-red coloured pigment of henna is a molecule called Lawson which is responsible for anti-microbial, anti-tumor, anti-inflammatory and analgesic activity. Chitosan is a biopolymer with high strength, biocom-patibility and biodegradability, non-toxicity and antimicrobial properties. Electrospinning is a method of producing su-bmicron polymeric fibers with high porosity and high s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2011