Evaluation of two commercial kits for serum gastrin assay, and comparison with a conventional radioimmunoassay procedure.

نویسندگان

  • R G Gibson
  • B I Hirschowitz
  • A A Mihas
چکیده

We compared two gastrin radioimmunoassay kits ("Immutope" kit, Squibb & Co.; "Gastrin R.I.A." kit, Schwarz/Mann) to the conventional gastrin radioimmunoassay of Yalow and Berson [Gastroenterology 58, 1 (1970)] as run by us and by a second reference laboratory. Although both kits were found to effectively discriminate above-normal and normal values for serum gastrin, they significantly underestimated very high values (greater than 1500 ng/liter). The Schwarz/Mann kit clearly had a superior quality label (lower nonspecific binding and higher specific activity) and a shorter incubation time. However, the 90-min incubation period cited for their kit caused overestimation of gastrin values in the lower range (5-300 ng/liter), which could be corrected by prolonging the incubation to 24 h. The Squibb antibody had fairly good cross reactivity to all gastrin species tested; the Schwarz/Mann antibody had poor affinity for natural human gastrin G34-II. Good correspondence was found for sera run by both reference laboratories (y = 0.96x + 10, r = 0.997), and values obtained with the Schwarz/Mann kit correlated best (+ 0.815) with those from the conventional radioimmunoassay procedure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

طراحی کیت اندازه‌گیری IgE اختصاصی آلرژن‌های شیر گاو به‌روش الایزا

Background: The hypersensitivity to cow’s milk allergens is the most common allergies in children at the first year of life. The specific IgE evaluation is one of the important methods in diagnosis of allergic disease. The aim of this study was development of a sensitive and credible procedure for detection of cow’s milk allergens specific IgE. Methods: The allergen discs...

متن کامل

Ten commercial kits compared for assay of thyrotropin in the normal and thyrotoxic range.

I developed a standard procedure for assessing sensitivity, intra-assay precision, parallelism of sample dilutions, and assay drift, using a single trial assay kit. I used this to compare the performance of 10 commercial kits with an in-house radioimmunoassay for human thyrotropin. No one kit stood out as clearly superior overall. Differences in calibration between kits were evident in a compar...

متن کامل

Positive interference in Radioimmunoassay determination of serum total T3

Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...

متن کامل

Three commercial methods for serum ferritin compared and the high-dose "hook effect" eliminated.

We evaluated four commercial kits for measuring serum ferritin, based on three techniques: immunoradiometric assay, radioimmunoassay, and enzyme immunoassay. The kits evaluated were those manufactured by Abbott Laboratories, Clinical Assays, Corning Medical, and Ramco. Two of the immunoradiometric kits showed satisfactory results with respect to sensitivity and precision; they should be useful ...

متن کامل

Comparison of countercurrent immunoelectrophoretic assay with commercial radioimmunoassay kits for measuring prostatic acid phosphatase.

We evaluated and compared five commercial radioimmunoassay kits with a standard counter-immunoelectrophoretic assay for the measurement of prostatic acid phosphatase in serum. Four of the five radioimmunoassays performed as described by the supplier with respect to sensitivity, stability, precision, linearity, analytical recovery, and expected values for the normal male population. None of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 1977