A Simple Method for the Evaluation of the Pulse Width of an Ultraviolet Femtosecond Laser Used in Two-Photon Ionization Mass Spectrometry
نویسندگان
چکیده
Tomoko Imasaka 1,*, Akifumi Hamachi 2, Tomoya Okuno 2 and Totaro Imasaka 2,3 1 Laboratory of Chemistry, Graduate School of Design, Kyushu University, Fukuoka 815-8540, Japan 2 Department of Applied Chemistry, Graduate School of Engineering, Kyushu University, Fukuoka 819-0395, Japan; [email protected] (A.H.); [email protected] (T.O.); [email protected] (T.I.) 3 Division of Optoelectronics and Photonics, Center for Future Chemistry, Kyushu University, Fukuoka 819-0395, Japan * Correspondence: [email protected]; Tel.: +81-92-553-4462
منابع مشابه
The study of propagation of a femtosecond laser pulse in the breast tissue
In this paper, the evaluation of time profile of a femtosecond pulse laser propagated through biological tissues is studied. The majority of the biological tissues with a high scattering anisotropy must be considered as turbid media, that their optical responses are complicated. To study the propagation of ultra-short pulse in turbid media, the diffuse equation is used. In this study, the analy...
متن کاملVacuum ultraviolet single photon versus femtosecond multiphoton ionization of sputtered germanium clusters.
Neutral atoms and clusters desorbed from a solid germanium surface by ion bombardment are detected by laser postionization and time-of-flight mass spectrometry. Two different photoionization schemes are compared which are generally believed to be candidates for the 'soft' ionization of polyatomic species without significant photon induced fragmentation. First, a single photon ionization process...
متن کاملNonresonant Femtosecond Laser Vaporization with Electrospray Postionization for <italic>ex vivo</italic> Plant Tissue Typing Using Compressive Linear Classification
T detection and identification of molecules within complex biological matrixes (i.e., plant tissue) requires homogenization, filtration, and liquid extraction of the sample to prepare for analysis using techniques such as gas chromatography/mass spectrometry (GC/MS), liquid chromatography-mass spectrometry (LC-MS), capillary electrophoresis-mass spectrometry (CE-MS), and LC-NMR. Direct analysis...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملA Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers
An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016