Photoelastic stress analysis of silastic poppets in prosthetic heart valves.
نویسندگان
چکیده
Some prosthetic heart valves with Silastic ball poppets undergo degeneration and variance. The problem is avoided with metal poppets; however, their impact can damage the cloth coverings on the struts, resulting in distorted blood flow paths. Consequently, renewed interest in mOd-cured Silastic poppets and inserts is developing. With photostress equipment, we analyzed two spherical poppet models to study poppet degeneration. The first analysis simulated the ring type of loading transmitted from the valve seat to the poppet, and the second analysis involved hydrostatic pressure loading and a detailed stress analysis to simiJate cage confrontation. Results showed that regions of the poppet were susceptible to stress cycling with relatively large tensions below the upper surface but above the ring support. This same location could experience large compressive stress, depending on how the poppet was positioned during a seating stroke. Shear stresses near the valve support ring were at least four times the hydrostatic pressure load. Such subsurface stress cycling should play a role in the formation of internal fissures that surface and fracture the poppet.
منابع مشابه
Clinical significance of multiple systolic clicks from Starr-Edwards prosthetic aortic valves.
The use of echocardiography, phonocardiography, and spectroanalysis has enhanced the ability to detect prosthetic valve dysfunction even before the onset of symptoms in many patients. Reduction in the intensity of the opening and closing clicks and the appearance of new murmurs have been the most frequently reported observations in predicting prosthetic valve dysfunction. Simultaneous echocardi...
متن کاملPregnancy Outcome with Intracytoplasmic Sperm Injection Method in a Woman with Prosthetic Heart Valves
There is an increased risk of thromboembolism, anticoagulant-related hemorrhage, fetal-wastage and congestive cardiac failure in pregnant women with mechanical heart valves. In order to have a good outcome, the care of such patients must necessarily be multidisciplinary and in a well- equipped centre with adequate support services .One such patient who had mechanical mitral and aortic valves re...
متن کاملMitral replacement: clinical experience with a ball-valve prosthesis. Twenty-five years later.
The purpose of this report is to review the results of mitral valve replacement since a first report in the Annals of Surgery in 1961, in order to determine the relative importance of new valve designs versus other surgical variables. The continued use of the silastic ball valve in its 1966 configuration (Model 6120), by providing a comparative data base for other new prosthetic valves, allows ...
متن کاملStress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis
Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...
متن کاملBacterial Endocarditis and Periodontal Disease
Bacterial endocarditis is the infection of inner lining of heart and /or heart valves. This disease is usually related to the presence of some pathogenic bacteria in mouth, digestive system or urinary tract. Most of the times, this infection happens in people with heart problems like the presence of prosthetic valves, history of previous endocarditis, some congenital heart defects and heart tra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation research
دوره 32 1 شماره
صفحات -
تاریخ انتشار 1973